| 数据搜索系统,热门电子元器件搜索 |
|
E5CZ-R2ML 数据表(PDF) 57 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CZ-R2ML 数据表(HTML) 57 Page - Omron Electronics LLC |
|
57 / 64 page ![]() E5EZ-PRR 57 Adjustment To adjust the PID constants, run AT. Settings for position proportional control When position proportional control is selected, "Closed/Floating", "Motor calibra- tion", "Travel time", "Position proportional dead band", "Open/Close hysteresis", "Operation at potentiometer input error", and "PV dead band" can be used. Closed/Floating • Closed control Control whereby a potentiometer is connected to feed back the amount of opening of the valve. • Floating control Control without feedback of the amount of opening of the valve. Control is possible without connecting a potentiometer. Motor calibration and travel time Run "Motor calibration" when a potentiometer is connected for closed control or floating control that monitors the amount of valve opening. This will also automatically set the "Travel time", which is the amount of time from when the valve is completely open to when the valve is completely closed. When performing floating control without a potentiometer, it is necessary to man- ually set the "Travel time". Set the travel time to the amount of time from when the valve is completely open to when the valve is completely closed. Position proportional dead band and Open/Close hysteresis The valve output hold interval (the duration of ON/OFF switching of open output and closed output) is set in "Position proportional dead band", and the hysteresis is set in "Open/Close hysteresis". The relation to valve opening is shown below. PV dead band When the present value is inside the PV dead band, this function is used to per- form control for PV = SP and stop unnecessary output when the PV is close to the SP. Operation at potentiometer input error Use this setting to select whether to stop control or switch to floating control and continue when a potentiometer error occurs during closed control. 0 Dead band −100% OFF ON 100% Open/close hysteresis MV-Valve opening |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |