| 数据搜索系统,热门电子元器件搜索 |
|
UM-YROTATE-IT-RX62T 数据表(PDF) 45 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
UM-YROTATE-IT-RX62T 数据表(HTML) 45 Page - Renesas Technology Corp |
|
45 / 54 page ![]() RX62T YROTATE-IT-RX62T Motor Control Kit UM-YROTATE-IT-RX62T Rev.1.00 Page 45 of 51 Jan 15, 2014 Troubleshooting: At the stage i) if the motor doesn’t start or generate an alarm n°3, please set the speed to “0” to clear the alarm which indicates that the software lost the phase. One first test is to increase or decrease the start-up current and the minimum speed or the speed PI gains When the motor is running, you can verify the number of pole pairs taking measurement of the effective speed, and comparing it with the imposed frequency: the number of pole pairs n is: n=freq*60/speed; if you change the number of pole pairs, remember to adjust also the minimum (and maximum) speed values. Sometimes the no load start-up is easier if the inductance parameter is set to 0. All the procedure is tuned to manage motors which maximum current is close to the inverter capability, which is around 6Arms for the external power stage (shunt=0.05Ohm) and 3Arms for the internal power stage (shunt=0.1Ohm); if you try to use it for very different motors, the results will be influenced by the losses in current reading resolution. Another possible trick when the things are very difficult, is trying to increase the flux feedback gain; sometimes I used 500 instead of 100. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |