| 数据搜索系统,热门电子元器件搜索 |
|
POWERSTEP01 数据表(PDF) 78 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
POWERSTEP01 数据表(HTML) 78 Page - STMicroelectronics |
|
78 / 92 page ![]() Programming manual powerSTEP01 78/92 DocID025022 Rev 5 This command can be given only when the previous motion command as been completed (BUSY flag released). Any attempt to perform a GoTo command when a previous command is under execution (BUSY low) causes the command to be ignored and the CMD_ERROR flag to rise (Section 11.1.28 on page 71). 11.2.9 GoTo_DIR (DIR, ABS_POS) The GoTo_DIR command produces a motion to ABS_POS absolute position imposing a forward (DIR = '1') or a reverse (DIR = '0') rotation. The ABS_POS value is always in agreement with the selected step mode; the parameter value unit is equal to the selected step mode (full, half, quarter, etc.). The GoTo_DIR command keeps the BUSY flag low until the target speed is reached. This command can be given only when the previous motion command has been completed (BUSY flag released). Any attempt to perform a GoTo_DIR command when a previous command is under execution (BUSY low) causes the command to be ignored and the CMD_ERROR flag to rise (Section 11.1.28). 11.2.10 GoUntil (ACT, DIR, SPD) The GoUntil command produces a motion at SPD speed imposing a forward (DIR = '1') or a reverse (DIR = '0') direction. When an external switch turn-on event occurs (Section 7.14 on page 33), the ABS_POS register is reset (if ACT = '0') or the ABS_POS register value is copied into the MARK register (if ACT = '1'); the system then performs a SoftStop command. The SPD value is expressed in step/tick (format unsigned fixed point 0.28) that is the same format as the SPEED register (Section 11.1.4 on page 53). The SPD value should be lower than MAX_SPEED and greater than MIN_SPEED, otherwise the target speed is imposed at MAX_SPEED or MIN_SPEED respectively. Table 68. GoTo_DIR command structure Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0110100 DIRFrom host X X ABS_POS (byte 2) From host ABS_POS (byte 1) From host ABS_POS (byte 0) From host Table 69. GoUntil command structure Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 1 0 0 0 ACT 0 1 DIR From host X X X X SPD (byte 2) From host SPD (byte 1) From host SPD (byte 0) From host |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |