39 / 58 page ![]() DocID028727 Rev 1 39/58 ST-PLC-AFE System timings and interruptions 58 9.3.2 Over temperature condition The ST-PLC-AFE contains protective, internal circuitry that automatically disables the PA output stage if the junction temperature exceeds 160 °C. The device also includes a thermal hysteresis which allows the PA to resume normal operation when the junction temperature falls to 145 °C. If a fault condition occurs that causes a thermal overload, the T_FLAG bit switches from 0 to 1. This configuration results in an interrupt signal at the INT pin. The T_FLAG bit remains set to 1 even after the device returns to normal operation. The T_FLAG bit remains 1 until it is reset by the microprocessor (when 0 is written inside the T_FLAG bit of the Status register). Another way to reset the T_FLAG bit is to use the RST_SPI system reset operation. Figure 39. Over temperature event |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|