19 / 40 page ![]() CC1050 SWRS044 Page 19 of 40 Write CAL: CAL_START=0 End of calibration Wait for maximum 26 ms, or Read CAL and wait until CAL_COMPLETE=1 Start single calibration Frequency register A is calibrated first Write MAIN: F_REG = 0; TX_PD = 0; FS_PD = 0 CORE_PD = 0; BIAS_PD = 0; RESET_N=1 Write FREQ_A, FREQ_B If DR>=38kBd then {write TEST4: L2KIO=3Fh, PRESCALER = 04h} Write CAL: CAL_DUAL = 0 Frequency register A and B are used for two different channels Write CAL: CAL_START=1 The result of the calibration is stored for frequency FREQ_A and can be read from the status registers TEST0 and TEST2 when F_REG = 0 Write CURRENT: VCO_CURRENT = Current Write PA_POW = 00h ‘Current’ is the VCO current to be used for both frequencies PA is turned off to prevent spurious emission Write CAL: CAL_START=0 Wait for 26 ms, or Read CAL and wait until CAL_COMPLETE=1 Frequency register B is calibrated second Write MAIN: F_REG = 1 Write CAL: CAL_START=1 Calibration time depend on the reference frequency, see text. The result of the calibration is stored for frequency FREQ_B and can be read from the status registers TEST0 and TEST2 when F_REG = 1 Write CAL: CAL_START=0 End of calibration Wait for maximum 26 ms, or Read CAL and wait until CAL_COMPLETE=1 Start single calibration Frequency register A is calibrated first Write MAIN: F_REG = 0; TX_PD = 0; FS_PD = 0 CORE_PD = 0; BIAS_PD = 0; RESET_N=1 Write FREQ_A, FREQ_B If DR>=38kBd then {write TEST4: L2KIO=3Fh, PRESCALER = 04h} Write CAL: CAL_DUAL = 0 Frequency register A and B are used for two different channels Write CAL: CAL_START=1 The result of the calibration is stored for frequency FREQ_A and can be read from the status registers TEST0 and TEST2 when F_REG = 0 Write CURRENT: VCO_CURRENT = Current Write PA_POW = 00h ‘Current’ is the VCO current to be used for both frequencies PA is turned off to prevent spurious emission Write CAL: CAL_START=0 Wait for 26 ms, or Read CAL and wait until CAL_COMPLETE=1 Frequency register B is calibrated second Write MAIN: F_REG = 1 Write CAL: CAL_START=1 Calibration time depend on the reference frequency, see text. The result of the calibration is stored for frequency FREQ_B and can be read from the status registers TEST0 and TEST2 when F_REG = 1 Figure 11. Single calibration algorithm for two different frequencies Not Recommended for New Designs |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |