| 数据搜索系统,热门电子元器件搜索 |
|
LP3933 数据表(PDF) 13 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LP3933 数据表(HTML) 13 Page - National Semiconductor (TI) |
|
13 / 18 page ![]() RGB Driver Electrical Characteristics (R1, G1, B1, R2, G2, B2 outputs) Symbol Parameter Conditions Min Typ Max Units R DS-ON ON Resistance I = 75 mA 3.5 6 Ω I LEAKAGE Off State Leakage Current V FB = 5V, LED driver off 0.03 1 µA I MAX Maximum Sink Current (Note 5) 120 mA T SMAX Maximum Slope Period At Maximum Duty Setting 0.93 s T SMIN Minimum Slope Period At Maximum Duty Setting 31 ms T SRES Slope Resolution At Maximum Duty Setting 62 ms T START/STOP Start/Stop Resolution Cycle 1s 1/16 s Duty Duty Step Size 6.25 % T BLINK Blinking Cycle Accuracy −6 ±3+6 % D CYCF Duty Cycle Range FLASH_MODE = 1 0 99.6 % D CYC Duty Cycle Range FLASH_MODE = 0 0 33.2 % D RESF Duty Resolution FLASH_MODE=1(4 bit) 6.64 % D RES Duty Resolution FLASH_MODE=0(4 bit) 2.21 % F PWMF PWM Frequency FLASH_MODE = 1 20 kHz F PWM PWM Frequency FLASH_MODE = 0 6.67 kHz RGB LED PWM Control (Note 15) R1DUTY[3:0] G1DUTY[3:0] B1DUTY[3:0] R2DUTY[3:0] G2DUTY[3:0] B2DUTY[3:0] DUTY sets the brightness of the LED by adjusting the duty cycle of the PWM driver. The minimum duty cycle is 0% [0000] and the maximum in the FLASH mode is A 100% [1111] of the peak pulse current. The peak pulse current is determined by the external resistor, LED voltage drop and the boost voltage. In normal mode the maximum duty cycle is 33%. R1SLOPE[3:0] G1SLOPE[3:0] B1SLOPE[3:0] R2SLOPE[3:0] G2SLOPE[3:0] B2SLOPE[3:0] SLOPE sets the turn-on and turn-off slopes. Fastest slope is set by [0000] and slowest by [1111]. SLOPE changes the duty cycle at constant, programmable rate. For each slope setting the maximum slope time appears at maximum DUTY setting. When DUTY is reduced, the slope time decreases proportionally. For example, in case of maximum DUTY, the sloping time can be adjusted from 31 ms [0000] to 930 ms [1111]. For 50% DUTY [0111] the sloping time is 14 ms [0000] to 434 ms [1111]. The blinking cycle has no effect on SLOPE. R1ON[3:0] G1ON[3:0] B1ON[3:0] R2ON[3:0] G2ON[3:0] B2ON[3:0] ON sets the beginning time of the turn-on slope. The on-time is relative to the selected blinking cycle length. On-setting N (N = 0–15) sets the on-time to N/16 * cycle length. R1OFF[3:0] G1OFF[3:0] B1OFF[3:0] R2OFF[3:0] G2OFF[3:0] B2OFF[3:0] OFF sets the beginning time of the turn-off slope. Off-time is relative to the blinking cycle length in the same way as the on-time. If ON=0,OFF=0 and RGB_PWM = 1, then RGB outputs are continuously on (no blinking), the DUTY setting controls the brightness and the SLOPE setting is ignored. If ON and OFF are the same, but not 0, the RGB outputs are turned off. CYCLE[1:0] CYCLE sets the blinking cycle: [00] for 0.25s, [01] for 0.5s, [10] for 1s and [11] for 2s. CYCLE effects to all RGB LEDs. www.national.com 13 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |