| 数据搜索系统,热门电子元器件搜索 |
|
LM79 数据表(PDF) 16 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM79 数据表(HTML) 16 Page - National Semiconductor (TI) |
|
16 / 31 page ![]() Functional Description (Continued) 3.0 USING THE LM79 3.1 Power On When power is first applied, the LM79 performs a “power on reset” on several of its registers. The power on condition of registers in shown in Table I. Registers whose power on values are not shown have power on conditions that are indeterminate (this includes the value RAM and WATCH- DOG limits). The ADC is inactive. In most applications, usu- ally the first action after power on would be to write WATCH- DOG limits into the Value RAM. 3.2 Resets Configuration Register INITIALIZATION accomplishes the same function as power on reset on most registers. The POST RAM, Value RAM conversion results, and Value RAM WATCHDOG limits are not Reset and will be indeterminate immediately after power on. If the Value RAM contains valid conversion results and/or Value RAM WATCHDOG limits have been previously set, they will not be affected by a Configuration Register INITIALIZATION. Power on reset, or Configuration Register INITIALIZATION, clear or initialize the following registers (the initialized values are shown on Table 1): • Configuration Register • Interrupt Status Register 1 • Interrupt Status Register 2 • SMI Mask Register 1 • SMI Mask Register 2 • NMI Mask Register 1 • NMI Mask Register 2 • VID/Fan Divisor Register • Serial Bus Address Register (Power on reset only, not reset by Configuration Register INITIALIZATION) Configuration Register INITIALIZATION is accomplished by setting Bit 7 of the Configuration Register high. This bit automatically clears after being set. The LM79 allows the user to perform an unconditional com- plete Power-on reset by writing a one to Bit 5 of the Chip Reset/VID4/Device ID Register. The LM79 allows an uncon- ditional complete Power-on reset to be initiated by taking the IOWR and IORD signal lines low simultaneously, for at least 50 ns, while CS is high. The delay between consecutive IORD and IOWR pulses should be greater than 50 ns to ensure that an Power-on reset does not occur unintention- ally. In systems where the serial bus is only being used it may be advantageous to take both IOWR and IORD to the system reset pulse. In this way whenever the system is reset the LM79 will also be reset to its initial Power-on state. 3.3 Using the Configuration Register The Configuration Register provides all control over the LM79. At power on, the ADC is stopped and INT__Clear is asserted, clearing the SMI and NMI/IRQ hardwire outputs. The Configuration Register starts and stops the LM79, en- ables and disables interrupt outputs and modes, and pro- vides the Reset function described in Section 3.2. Bit 0 of the Configuration Register controls the monitoring loop of the LM79. Setting Bit 0 low stops the LM79 monitor- ing loop and puts the LM79 in shutdown mode, reducing power consumption. ISA and Serial Bus communication is possible with any register in the LM79 although activity on these lines will increase shutdown current, up to as much as maximum rated supply current, while the activity takes place. Taking Bit 0 high starts the monitoring loop, described in more detail subsequently. Bit 1 of the Configuration Register enables the SMI Interrupt hardwire output when this bit is taken high. Similarly, Bit 2 of the Configuration Register enables the NMI/IRQ Interrupt hardwire output when taken high. The NMI/IRQ mode is determined by Bit 5 in the Configuration Register. When Bit 5 is low the output is an active low IRQ output. Taking Bit 5 high inverts this output to provide an active high NMI output. The Power Switch Bypass provides an active low at the open drain Power Switch Bypass output when set high. This is intended for use in software power control by activating an external power control MOSFET. 3.4 Starting Conversion The monitoring function (Analog inputs, temperature, and fan speeds) in the LM79 is started by writing to the Configu- ration Register and setting INT__Clear (Bit 3), low, and Start (bit 0), high. The LM79 then performs a “round-robin” moni- toring of all analog inputs, temperature, and fan speed inputs approximately once a second. The sequence of items being monitored corresponds to locations in the Value RAM and is: 1. Temperature 2. IN0 3. IN1 4. IN2 5. IN3 6. IN4 7. -IN5 8. -IN6 9. Fan 1 10. Fan 2 11. Fan 3 3.5 Reading Conversion Results The conversion results are available in the Value RAM. Conversions can be read at any time and will provide the result of the last conversion. Because the ADC stops, and starts a new conversion whenever it is read, reads of any single value should not be done more often then once every 120 ms. When reading all values, allow at least 1.5 seconds between reading groups of values. Reading more frequently than once every 1.5 seconds can also prevent complete updates of Interrupt Status Registers and Interrupt Output’s. A typical sequence of events upon power on of the LM79 would consist of: 1. Set WATCHDOG Limits 2. Set Interrupt Masks 3. Start the LM79 monitoring process 4.0 ANALOG INPUTS The 8-bit ADC has a 16 mV LSB, yielding a 0V to 4.08V (4.096–1LSB) input range. This is true for all analog inputs. In PC monitoring applications these inputs would most often be connected to power supplies. The 2.5V and 3.3V supplies can be directly connected to the inputs. The 5V and 12V inputs should be attenuated with external resistors to any desired value within the input range. www.national.com 16 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |