| 数据搜索系统,热门电子元器件搜索 |
|
CS3.241 数据表(PDF) 13 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS3.241 数据表(HTML) 13 Page - PULS GmbH |
|
13 / 24 page ![]() CS3.241 C-Line 24V, 3.3A, SINGLE PHASE INPUT 13. EMC The power supply is suitable for applications in industrial environment as well as in residential, commercial and light industry environment. A detailed EMC report is available on request. EMC Immunity According generic standards: EN 61000-6-1 and EN 61000-6-2 Electrostatic discharge EN 61000-4-2 contact discharge air discharge 8kV 15kV Criterion A Criterion A Electromagnetic RF field EN 61000-4-3 80MHz-2.7GHz 10V/m Criterion A Fast transients (Burst) EN 61000-4-4 input lines output lines 4kV 2kV Criterion A Criterion A Surge voltage on input EN 61000-4-5 L N L PE, N PE 2kV 4kV Criterion A Criterion A Surge voltage on output EN 61000-4-5 + - + / - PE 500V 1kV Criterion A Criterion A Conducted disturbance EN 61000-4-6 0.15-80MHz 10V Criterion A Mains voltage dips EN 61000-4-11 0% of 100Vac 40% of 100Vac 70% of 100Vac 0% of 200Vac 40% of 200Vac 70% of 200Vac 0Vac, 20ms 40Vac, 200ms 70Vac, 500ms 0Vac, 20ms 80Vac, 200ms 140Vac, 500ms Criterion B *) Criterion C Criterion A Criterion A Criterion A Criterion A Voltage interruptions EN 61000-4-11 5000ms Criterion C Powerful transients VDE 0160 over entire load range 750V, 1.3ms Criterion A Criterions: A: Power supply shows normal operation behavior within the defined limits. B: Temporary voltage dips possible. No change in operation mode. C: Temporary loss of function is possible. Power supply may shut-down and restarts by itself. No damage or hazards for the power supply will occur. *): Criterion A is fulfilled below 2.8A output current EMC Emission According generic standards: EN 61000-6-3, EN 61000-6-4 Conducted emission input lines EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 Class B Conducted emission output lines**) IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 limits for DC power port according EN 61000-6-3 not fulfilled Radiated emission EN 55011, EN 55022 Class B Harmonic input current EN 61000-3-2 fulfilled Voltage fluctuations, flicker EN 61000-3-3 fulfilled*) This device complies with FCC Part 15 rules. Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. *) tested with constant current loads, non pulsing **) for information only, not mandatory for EN 61000-6-3 Switching frequency 50kHz to 450kHz Main converter, input voltage and load dependent Jul. 2015 / Rev. 2.0 DS-CS3.241-EN All parameters are specified at 24V, 3.3A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 13/24 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |