| 数据搜索系统,热门电子元器件搜索 |
|
CS3.241 数据表(PDF) 23 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS3.241 数据表(HTML) 23 Page - PULS GmbH |
|
23 / 24 page ![]() CS3.241 C-Line 24V, 3.3A, SINGLE PHASE INPUT 22.7. SERIES OPERATION Unit A AC DC Unit B AC DC - + - + Load + - Earth (see notes) Power supplies of the same type can be connected in series for higher output voltages. It is possible to connect as many units in series as needed, providing the sum of the output voltage does not exceed 150Vdc. Voltages with a potential above 60Vdc are no longer SELV and can be dangerous. Such voltages must be installed with a protection against touching. Earthing of the output is required when the sum of the output voltage is above 60Vdc. Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. Keep an installation clearance of 15mm (left / right) between two power supplies and avoid installing the power supplies on top of each other. Do not use power supplies in series in mounting orientations other than the standard mounting orientation (input terminals on bottom of the unit). Pay attention that leakage current, EMI, inrush current, harmonics will increase when using multiple power supplies. 22.8. INDUCTIVE AND CAPACITIVE LOADS The unit is designed to supply any kind of loads, including capacitive and inductive loads. 22.9. OPERATION ON TWO PHASES Fuse L2 L1 L3 L N PE Power Supply AC DC internal fuse The power supply can also be used on two-phases of a three-phase-system. A phase-to-phase connection is allowed as long as the supplying voltage is below 240V+10%. 22.10.USE IN A TIGHTLY SEALED ENCLOSURE When the power supply is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher than outside. In such situations, the inside temperature defines the ambient temperature for the power supply. The following measurement results can be used as a reference to estimate the temperature rise inside the enclosure. The power supply is placed in the middle of the box, no other heat producing items are inside the box Enclosure: Rittal Typ IP66 Box PK 9516 100, plastic, 110x180x165mm Input: 230Vac Load: 24V, 3.3A; (=100%) load is placed outside the box Temperature inside enclosure: 45.7°C (in the middle of the right side of the power supply with a distance of 2cm) Temperature outside enclosure: 27.3°C Temperature rise: 18.4K Load: 24V, 2.64A; (=80%) load is placed outside the box Temperature inside enclosure: 41.8°C (in the middle of the right side of the power supply with a distance of 2cm) Temperature outside enclosure: 26.5°C Temperature rise: 15.3K Jul. 2015 / Rev. 2.0 DS-CS3.241-EN All parameters are specified at 24V, 3.3A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 23/24 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |