| 数据搜索系统,热门电子元器件搜索 |
|
CS3.241 数据表(PDF) 8 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS3.241 数据表(HTML) 8 Page - PULS GmbH |
|
8 / 24 page ![]() CS3.241 C-Line 24V, 3.3A, SINGLE PHASE INPUT 7. HOLD-UP TIME AC 100V AC 120V AC 230V Hold-up Time typ. 38ms 60ms 244ms at 24V, 1.65A, see Fig. 7-1 min. 29ms 45ms 200ms at 24V, 1.65A, see Fig. 7-1 typ. 19ms 29ms 120ms at 24V, 3.3A, see Fig. 7-1 min. 15ms 23ms 95ms at 24V, 3.3A, see Fig. 7-1 Fig. 7-1 Hold-up time vs. input voltage Fig. 7-2 Shut-down behavior, definitions 0 25 50 75 100 225ms 85 120 155 190 230Vac Input Voltage 125 150 175 Hold-up Time 200 24V, 3.3A, min. 24V, 3.3A, typ. 24V, 1.65A, min. 24V, 1.65A, typ. - 5% Hold-up Time Zero Transition Output Voltage Input Voltage Note: At no load, the hold-up time can be up to several seconds. The green DC-OK lamp is on during this time. Jul. 2015 / Rev. 2.0 DS-CS3.241-EN All parameters are specified at 24V, 3.3A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 8/24 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |