| 数据搜索系统,热门电子元器件搜索 |
|
QS10.DNET 数据表(PDF) 10 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
QS10.DNET 数据表(HTML) 10 Page - PULS GmbH |
|
10 / 22 page ![]() QS10.DNET Q-Series 24V, 8A, DEVICENET® POWER SUPPLY 11. FUNCTIONAL DIAGRAM Fig. 11-1 Functional diagram + + - - DC-ok contact Output Over- Voltage Protection PFC Converter Output Voltage Regulator Power Converter Output Filter DC-ok Relay Output Voltage Monitor Output Power Manager Temper- ature Shut- down Overload LED DC-ok LED Input Fuse Input Filter Input Rectifier Active Transient Filter & Inrush Current Limiter V OUT L N 12. TERMINALS AND WIRING Bi-stable, quick-connect spring clamp terminals. IP20 Finger safe construction. Suitable for field- and factory installation. Shipped in open position. Input Output DC-OK-Signal Type spring-clamp terminals spring-clamp terminals spring-clamp terminals Solid wire 0.5-6mm2 0.5-6mm2 0.5-6mm2 Stranded wire 0.5-4mm2 0.5-4mm2 0.5-4mm2 American Wire Gauge 20-10 AWG 20-10 AWG 20-10 AWG Wire stripping length 10mm / 0.4inch 10mm / 0.4inch 10mm / 0.4inch Screwdriver not applicable not applicable not applicable Recommended tightening torque not applicable not applicable not applicable Pull-out force 10AWG:80N, 12AWG:60N, 14AWG:50N, 16AWG:40N (according to UL486E) Fig. 12-1 Connecting a wire Instructions: a) Use appropriate copper cables that are designed for minimum operating temperatures of: 60°C for ambient up to 45°C and 75°C for ambient up to 60°C minimum 90°C for ambient up to 70°C minimum. b)Follow national installation codes and installation regulations! c) Ensure that all strands of a stranded wire enter the terminal connection! d)Up to two stranded wires with the same cross section are permitted in one connection point (except PE wire). e) Do not use the unit without PE connection. f) Unused terminal compartments should be securely tightened. g)Ferrules are allowed. 1. Insert the wire 2. Close the lever To disconnect wire: reverse the procedure Dec. 2014 / Rev. 2.2 DS-QS10.DNET-EN All parameters are specified at 24V, 8A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/22 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |