33 / 51 page ![]() DocID028688 Rev 6 33/51 L9301 Combined diagnosis (configuration 1, 2 & 3) 50 10 Combined diagnosis (configuration 1, 2 & 3) In configuration 1, there are four couples of drivers in parallel to get four channels with lower RdsON: OUT1 with OUT2, OUT3 with OUT4, HS1 with HS2, and HS3 with HS4. For each couple, only one driver off diagnosis is enabled (OUT1, OUT3, HS1, HS3) while the off diagnosis results are stored in both drivers registers. The other diagnosis of the two drivers in parallel, as over-current, over-temperature and DLOSS, are both enabled. In configuration 2 the off diagnosis is enabled for OUT1-4 only. Considering that the diagnosis blanking time can be longer than the off time of PWM, the diagnosis results can be affected. The short to GND fault can be detected by the HS OC fault when it is switched on. The Open Load Fault can be detected when PWM is disabled (PWM disable SPI bit = 1) only because in such a condition both HS and LS are OFF. In this condition the OUTx is pulled down by LS off diagnosis pull down current (typical 70 μA) and it's necessary to wait the time needed to discharge OUTx to get Open Load (OL) detection. The time to be considered starts from the PWM disable bit writing. In configuration 3 the off diagnosis is enabled for HS1-4 only. Considering that the diagnosis blanking time can be longer than the off time of PWM, the diagnosis results can be affected. The short to VB fault can be detected by the OC fault when it is switched on. The Open Load Fault can be detected when PWM is disabled (PWM disable SPI bit = 1) only because in such a condition both HS and LS are OFF. In this condition the OUTx is pulled up by HS off diagnosis pull up current (typical 75 μA) and it's necessary to wait the time needed to discharge OUTx to get Open Load (OL) detection. The time to be considered starts from the PWM disable bit writing. In PWM mode, configuration 2 and 3, unless the PWM enable SPI bit for OUT1-4 and DRN/SRC1-4 are set, the eight drivers are all switched off. Table 22. Configuration 2 Parameter Test condition Min. Typ. Max. Unit Minimum OFF time for correct diagnostic (Blank time 0) Application note NOT TESTED (ESD cap < 12 nF, Bit_blank = 0) 4140 - - μs Minimum OFF time for correct diagnostic (Blank time 1) Application note NOT TESTED (ESD cap < 6 nF, Bit_blank=1) 2190 - - μs Table 23. Configuration 3 Parameter Test condition Min. Typ. Max. Unit Minimum OFF time for correct diagnostic (Blank time 0) Application note NOT TESTED (ESD cap < 12 nF, Bit_blank = 0) 980 - - μs Minimum OFF time for correct diagnostic (Blank time 1) Application note NOT TESTED (ESD cap < 6 nF, Bit_blank=1) 530 - - μs |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |