| 数据搜索系统,热门电子元器件搜索 |
|
CP20.241-R2 数据表(PDF) 18 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP20.241-R2 数据表(HTML) 18 Page - PULS GmbH |
|
18 / 30 page ![]() CP20.241-R1, CP20.241-R2, CP20.241-R3 CP-Series 24V, 20A, SINGLE PHASE INPUT June 2017 / Rev. 0.1 DS-CP20.241-R2-EN All parameters are typical values specified at 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 18/30 P R E L I M I N A R Y 18. PROTECTION FEATURES Output protection Electronically protected against overload, no-load and short-circuits. In case of a protection event, audible noise may occur. Output over-voltage protection typ. 30.5Vdc max. 32Vdc In case of an internal power supply defect, a redundant circuit limits the maximum output voltage. The output shuts down and automatically attempts to restart. Degree of protection IP 20 EN/IEC 60529 Penetration protection > 5mm E.g. screws, small parts Over-temperature protection yes1) Output shut-down with automatic restart Input transient protection MOV (Metal Oxide Varistor) For protection values see chapter 16 (EMC). Internal input fuse included Not user replaceable slow-blow high-braking capacity fuse 1) The temperature sensor is installed inside the isolating transformer and turns the unit off in safety critical situations (e.g. de-rating requirements not observed, high ambient temperature, ventilation obstructed or the mounting orientation de-rating is not followed). There is no correlation between the operating temperature and turn-off temperature since this is dependent on input voltage, load and installation methods. There is no correlation between the operating temperature and turn-off temperature since this is dependent on input voltage, load and installation methods. 19. SAFETY FEATURES Input / output separation Double or reinforced galvanic isolation SELV IEC/EN 60950-1 PELV IEC/EN 60204-1, EN 62477-1, IEC 60364-4-41 Class of protection I PE (Protective Earth) connection required Isolation resistance > 500MOhm At delivered condition between input and output, measured with 500Vdc > 500MOhm At delivered condition between input and PE, measured with 500Vdc > 500MOhm At delivered condition between output and PE, measured with 500Vdc > 500MOhm At delivered condition between output and DC-OK contacts, measured with 500Vdc PE resistance < 0.1Ohm Resistance between PE terminal and the housing in the area of the DIN-rail mounting bracket. Touch current (leakage current) typ. 0.12mA / 0.31mA At 100Vac, 50Hz, TN-,TT-mains / IT-mains typ. 0.18mA / 0.45mA At 120Vac, 60Hz, TN-,TT-mains / IT-mains typ. 0.30mA / 0.76mA At 230Vac, 50Hz, TN-,TT-mains / IT-mains max. 0.16mA / 0.38mA At 110Vac, 50Hz, TN-,TT-mains / IT-mains max. 0.23mA / 0.55mA At 132Vac, 60Hz, TN-,TT-mains / IT-mains max. 0.39mA / 0.94mA At 264Vac, 50Hz, TN-,TT-mains / IT-mains |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |