25 / 30 page ![]() CP20.241-R1, CP20.241-R2, CP20.241-R3 CP-Series 24V, 20A, SINGLE PHASE INPUT June 2017 / Rev. 0.1 DS-CP20.241-R2-EN All parameters are typical values specified at 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 25/30 P R E L I M I N A R Y 25.2. ADJUSTING THE OUTPUT VOLTAGE A voltage adjustment potentiometer can be found behind the flap on the front of the unit (see chapter 15). However, it is not recommended to change the output voltage since load sharing between power supplies connected in parallel can only be achieved by a precise setting of the output voltages. The factory settings allow precise load sharing and only qualified personnel should change the adjustment potentiometer. Adjustment range min. 24 - 28V Please note the “soft output regulation characteristic” where the voltage at no load is approx. 4% higher than at nominal load. See chapter 6 for details. max. 30V Maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not a guaranteed value which can be achieved. The typical value is about 29.5V. Output current at 28V nom. 20.6A Below +45°C ambient nom. 17.1A At +60°C ambient nom 13.0A At +70°C ambient Current values between 24V and 28V can be interpolated. The output voltage shall only be changed when absolutely necessary, e.g. for battery charging. 25.3. CHARGING OF BATTERIES This redundancy power supply is ideal for charging batteries due to the decoupling circuit built in to the output stage which does not require a fuse or diode between the power supply and the battery. It can be used to charge sealed lead acid (SLA) or valve regulated lead acid (VRLA) lead batteries when following these instructions: a) Set output voltage (measured at disconnected battery) very precisely to the end-of-charge voltage. Use the potentiometer, which is hidden behind the flap on the front of the unit. Battery temperature 10°C 20°C 30°C 40°C End-of-charge voltage 27.8V 27.5V 27.15V 26.8V b) Ensure that the ambient temperature of the power supply stays below 40°C. c) Use only matched batteries when putting 12V types in series. d) The return current to the power supply (battery discharge current) is typically 11mA when the power supply is switched off. 25.4. BACK-FEEDING LOADS Loads such as decelerating motors and inductors can feed voltage back to the power supply. This feature is also called return voltage immunity or resistance against Back- E.M.F. (Electro Magnetic Force). This power supply is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is on or off. The maximum allowed feed-back-voltage is 35Vdc. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |