7 / 30 page ![]() CP20.241-R1, CP20.241-R2, CP20.241-R3 CP-Series 24V, 20A, SINGLE PHASE INPUT June 2017 / Rev. 0.1 DS-CP20.241-R2-EN All parameters are typical values specified at 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 7/30 P R E L I M I N A R Y 6. OUTPUT Output voltage nom. DC 24V 0%/+6% The device is featured with a “soft output regulation characteristic” in order to achieve current share between multiple devices, when they are connected in parallel. The “soft output regulation characteristic” regulates the output voltage in such a manner that the voltage at no load is approx. 4% higher than at nominal load. Adjustment range See chapter 25.2 Factory settings typ. 24.1V ±0.2%, at full load, cold unit typ. 25.1V At no load, cold unit Line regulation max. 10mV 85-300Vac Load regulation typ. 1000mV Static value, 0A 20A; see Fig. 6-1 Ripple and noise voltage max. 50mVpp 20Hz to 20MHz, 50Ohm Output current nom. 24A1) Below 45°C ambient temperature, see Fig. 17-1 nom. 20A At 60°C ambient temperature, see Fig. 17-1 nom. 15A At 70°C ambient temperature, see Fig. 17-1 typ. 60A Up to 12ms once every five seconds, see Fig. 6-3 The output voltage stays above 20V. See chapter 25.1 for more peak current measurements. Overload behaviour Continuous current Output voltage > 13Vdc, see Fig. 6-1 HiccupPLUS® mode2) Output voltage < 13Vdc, see Fig. 6-1 Short-circuit current min. 26A3) Load impedance <10mOhm, see Fig. 6-1 max. 31A3) Load impedance <10mOhm, see Fig. 6-1 max. 9.8A3) Average (R.M.S.) current, load impedance 50mOhm, see Fig. 6-2. min. 55A Up to 12ms, load impedance <10mOhm, see Fig. 6-3 typ. 70A Up to 12ms, load impedance <10mOhm, see Fig. 6-3 Output capacitance typ. 8 000μF Included inside the power supply 1) Power Boost This power/ current is continuously allowed up to an ambient temperature of 45°C. Above 45°C, do not use this power/ current longer than a duty cycle of 10% and/ or not longer than 1 minute every 10 minutes. 2) HiccupPLUS® Mode At heavy overloads (when output voltage falls below 13V), the power supply delivers continuous output current for 2s. After this, the output is switched off for approx. 18s before a new start attempt is automatically performed. This cycle is repeated as long as the overload exists. If the overload has been cleared, the device will operate normally. See Fig. 6-2. 3) Discharge current of output capacitors is not included. Fig. 6-1 Output voltage vs. output current, typ. Fig. 6-2 Short-circuit on output, HiccupPLUS mode, typ. Output Voltage 0 4 8 12 28V 16 20 24 025 40A 15 5 10 20 30 35 Output Current Continuous current HiccupPLUS mode Output Current 0 29A 18s t 18s 18s 2s 2s 2s Short -circuit Normal operation Normal operation |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |