7 / 18 page ![]() uP9303 7 uP9303-DS-F0101, Aug. 2017 www.upi-semi.com An OCP will shut down the device and discharge the C SS with a 30uA sinking current source. When the C SS is discharged completely, another soft start cycle is initiated. If the over current condition is not removed during the soft start cycle, the uP9303 will shut down immediately when another OCP is triggered. However, the V SS keeps rising to 4V to complete the soft start cycle before the internal 30uA current source discharges the C SS. If the over current conditon is not removed, the re-soft-start cycle will repeat 3 times and then latch off uP9303. To avoid false trigger of OCP, variations of all parameters in above equation should be well considered, including: 1.) The R DS(ON) of MOSFET varies with temperature and the gate to source voltage. Consider the highest operation temperature and lowest gate to source voltage. 2.) Consider the minimum I OCSET (~180uA) and minimum R OCSET. 3.) Consider the inductor ripple current. Functional Description 2.4V Current Limited Local Clock Generator Clock Logic Clock Logic Remote Clock (RC): RC Frequency > 50kHz Local Clock (LC): 2V < VFSET < 3V for 30us Clock Off: Otherwise Ramp Generator Sampled and Held Current Ramp FSET/SYN CLK To turn off the current source when RC = 1 for local clock for remote clock Under Voltage Protection (UVP) The FB voltage is monitored for undervoltage protection after soft start end is asserted. If the FB voltage is lower than 0.3V (50% of 0.6V reference voltage), the UVP is triggered and shuts down the uP9303 with about 10us time delay. The uP9303 turns off both upper and lower MOSFETs when UVP is triggered. The UVP is a latch-off type protection and can only be reset by POR of the device. Over Voltage Protection (OVP) The FB voltage is monitored for overvoltage protection. If the FB voltage is higher than 0.78V (130% of 0.6V reference voltage), the OVP is triggered and shuts down the uP9303 with about 10us time delay. The uP9303 turns off the upper and lower MOSFET when OVP is triggered. The OVP is a latch-off type protection and can only be reset by POR of the device. Figure 4. Clock Logic of uP9303 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |