| 数据搜索系统,热门电子元器件搜索 |
|
PIC18LF4520E/SPQTP 数据表(PDF) 143 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC18LF4520E/SPQTP 数据表(HTML) 143 Page - Microchip Technology |
|
143 / 390 page ![]() 2004 Microchip Technology Inc. Preliminary DS39631A-page 141 PIC18F2420/2520/4420/4520 15.2 Capture Mode In Capture mode, the CCPRxH:CCPRxL register pair captures the 16-bit value of the TMR1 or TMR3 registers when an event occurs on the corresponding CCPx pin. An event is defined as one of the following: • every falling edge • every rising edge • every 4th rising edge • every 16th rising edge The event is selected by the mode select bits, CCPxM3:CCPxM0 (CCPxCON<3:0>). When a capture is made, the interrupt request flag bit, CCPxIF, is set; it must be cleared in software. If another capture occurs before the value in register CCPRx is read, the old captured value is overwritten by the new captured value. 15.2.1 CCP PIN CONFIGURATION In Capture mode, the appropriate CCPx pin should be configured as an input by setting the corresponding TRIS direction bit. 15.2.2 TIMER1/TIMER3 MODE SELECTION The timers that are to be used with the capture feature (Timer1 and/or Timer3) must be running in Timer mode or Synchronized Counter mode. In Asynchronous Counter mode, the capture operation will not work. The timer to be used with each CCP module is selected in the T3CON register (see Section 15.1.1 “CCP Modules and Timer Resources”). 15.2.3 SOFTWARE INTERRUPT When the Capture mode is changed, a false capture interrupt may be generated. The user should keep the CCPxIE interrupt enable bit clear to avoid false inter- rupts. The interrupt flag bit, CCPxIF, should also be cleared following any such change in operating mode. 15.2.4 CCP PRESCALER There are four prescaler settings in Capture mode; they are specified as part of the operating mode selected by the mode select bits (CCPxM3:CCPxM0). Whenever the CCP module is turned off or Capture mode is disabled, the prescaler counter is cleared. This means that any Reset will clear the prescaler counter. Switching from one capture prescaler to another may generate an interrupt. Also, the prescaler counter will not be cleared; therefore, the first capture may be from a non-zero prescaler. Example 15-1 shows the recommended method for switching between capture prescalers. This example also clears the prescaler counter and will not generate the “false” interrupt. EXAMPLE 15-1: CHANGING BETWEEN CAPTURE PRESCALERS (CCP2 SHOWN) FIGURE 15-1: CAPTURE MODE OPERATION BLOCK DIAGRAM Note: If RB3/CCP2 or RC1/CCP2 is configured as an output, a write to the port can cause a capture condition. CLRF CCP2CON ; Turn CCP module off MOVLW NEW_CAPT_PS ; Load WREG with the ; new prescaler mode ; value and CCP ON MOVWF CCP2CON ; Load CCP2CON with ; this value CCPR1H CCPR1L TMR1H TMR1L Set CCP1IF TMR3 Enable Q1:Q4 CCP1CON<3:0> CCP1 pin Prescaler ÷ 1, 4, 16 and Edge Detect TMR1 Enable T3CCP2 T3CCP2 CCPR2H CCPR2L TMR1H TMR1L Set CCP2IF TMR3 Enable CCP2CON<3:0> CCP2 pin Prescaler ÷ 1, 4, 16 TMR3H TMR3L TMR1 Enable T3CCP2 T3CCP1 T3CCP2 T3CCP1 TMR3H TMR3L and Edge Detect 4 4 4 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |