| 数据搜索系统,热门电子元器件搜索 |
|
CUB5COM2 数据表(PDF) 6 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CUB5COM2 数据表(HTML) 6 Page - Red Lion Controls. Inc |
|
6 / 16 page ![]() 6 5.0 reviewinG the front ButtonS and diSplay SEL RST PROGRAMMING MODE ENTRY (SEL KEY) It is recommended all programming changes be made off line, or before installation. The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing and holding the SEL key. If it is not accessible then it is locked by either a security code, or a hardware lock. MODULE ENTRY (SEL & RST KEYS) The Programming Menu is organized into separate modules. These modules group together parameters that are related in function. The display will alternate between Pro and the present module. The RST key is used to select the desired module. The displayed module is entered by pressing the SEL key. MODULE MENU (SEL KEY) Each module has a separate module menu (which is shown at the start of each module discussion). The SEL key is pressed to advance to a particular parameter to be changed, without changing the programming of preceding parameters. After completing a module, the display will return to Pro NO. Programming may continue by accessing additional modules. SELECTION / VALUE ENTRY For each parameter, the display alternates between the present parameter and the selections/value for that parameter. The RST key is used to move through the selections/values for that parameter. Pressing the SEL key, stores and activates the displayed selection/value. This also advances the meter to the next parameter. For numeric values, press the RST key to access the value. The right hand most digit will begin to flash. Pressing the RST key again increments the digit by one or the user can hold the RST key and the digit will automatically scroll. The SEL key will advance to the next digit. Pressing and holding the SEL key will enter the value and move to the next parameter. PROGRAMMING MODE EXIT (SEL KEY) The Programming Mode is exited by pressing the SEL key with Pro NO displayed. This will commit any stored parameter changes to memory and return the meter to the Display Mode. (If power loss occurs before returning to the Display Mode, verify recent parameter changes.) PROGRAMMING TIPS It is recommended to start with Module 1 for counting or Module 2 for rate. When programming is complete, it is recommended to record the parameter programming and lock out parameter programming with the user input or programming security code. FACTORY SETTINGS Factory settings may be completely restored in Module 3. This is useful when encountering programming problems. ALTERNATING SELECTION DISPLAY In the explanation of the modules, the following dual display with arrows will appear. This is used to illustrate the display alternating between the parameter on top and the parameter’s factory setting on the bottom. In most cases, selections and values for the parameter will be listed on the right. 6.0 proGraMMinG the Meter Parameters Output Setpoint Parameters Input Setup Pro DISPLAY MODE Panel Key Rate Setup Parameters 3-dSPLAY Parameters Display and Front NO SEL RST SEL SEL SEL SEL 2-rAtE 1-INPUt 4-SEtPt 5-SEriAL SEL Serial Setup Parameters OVERVIEW PROGRAMMING MENU Indicates Program Mode Alternating Display Factory Settings are shown. Parameter Selection/Value KEY DISPLAY MODE OPERATION ENTERING PROGRAM MODE PROGRAMMING MODE OPERATION SEL Index display through enabled values Press and hold for 2 seconds to activate Store selected parameter and index to next parameter RST Resets count display(s) and/or outputs Advances through the program menu/ Increments selected parameter value or selection OPERATING MODE DISPLAY DESIGNATORS “R” - To the left of the display is the rate value. - Counter A has no designator. “b” - To the left of the display is the Counter B value (dual count or batch). “1” and “2” - Indicates setpoint 1 and 2 output status. Pressing the SEL button toggles the meter through the selected displays. If display scroll is enabled, the display will toggle automatically every four seconds between the rate and count values. Cnt ud INP A-b |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |