| 数据搜索系统,热门电子元器件搜索 |
|
CUB5COM2 数据表(PDF) 11 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CUB5COM2 数据表(HTML) 11 Page - Red Lion Controls. Inc |
|
11 / 16 page ![]() 11 6.4 Module 4 - Setpoint output paraMeterS (4-SEtPt) SEL Setpoint 2 Enable Setpoint Select Setpoint Assignment Setpoint Output Logic Setpoint Output Action Setpoint Value Setpoint Output Time-out SP2 Only Setpoint Annunciator SPt SEL 4-SEtPt SP2 Enb SPn ASN SPn ACt SPn tOUt SPn VAL SPn OUt SPn LIt PPrroo SPn P-UP SPn StbY Setpoint Standby Operation Setpoint Boundary Type SPn tYPE Counter Auto Reset SPn AUtO SPn ChC Change Display Color with Output State SP2 Output Off at SP1 Output SP1 Output Off at SP2 Output SP1 OFF2 SP2 OFF1 Setpoint Output Reset with Manual Reset SPn rSt Setpoint Output Power-up State SP1 Only SP2 Only Backlight Unit Only PARAMETER MENU The Setpoint Output Parameters are only active when an optional Setpoint Output Module is installed in the meter. Some parameters in the menu will not appear depending on the Setpoint Assignment and Setpoint Output Action. The Setpoint Parameter Availability chart below illustrates this. PARAMETER DESCRIPTION BOUNDARY bOUNd LATCH LAtCH RATE ASSIGNMENT TIMED OUT t-OUt BOUNDARY bOUNd LATCH LAtCH Yes No No Yes No No SPn VAL Setpoint Value Yes Yes Yes Yes Yes Yes SPn OUt Setpoint Output Logic Yes Yes Yes Yes Yes Yes SPn LIt Setpoint Annunciator Yes Yes Yes Yes Yes Yes SPn P-UP Setpoint Output Power-up State No No Yes No No Yes SPn tYPE Setpoint Boundary Type No Yes No Yes Yes Yes SPn StbY Standby Operation (Low acting only) No Yes No Yes Yes Yes SPn AUtO Counter Auto Reset Yes No Yes No No No SP1 OFF2 SP1 Output Off at SP2 (SP1 only) Yes No Yes No No No SP2 OFF1 SP2 Output Off at SP1 (SP2 only) Yes No Yes No No No SPn rSt Output Reset with Manual Reset Yes No Yes Yes No Yes SPn ChC Change Display Color w/ Output State Yes Yes Yes Yes Yes Yes Setpoint Output Time-out Value TIMED OUT t-OUt COUNTER ASSIGNMENT (A or B) * SPn tOUt * BOUNDARY Setpoint Action not applicable for Counter B Assignment Select the Setpoint Output to be programmed, starting with Setpoint 1. The "n" in the following parameters reflects the chosen Setpoint number. After Setpoint 1 is completely programmed, the display returns to SPt SEL. Repeat steps for Setpoint 2 if both Setpoints are used in the application. Select NO to exit the Setpoint programming module. The number of Setpoints available is dependent on the Setpoint option module installed. SETPOINT SELECT SP2 SP1 NO NO SPt SEL SETPOINT 2 ENABLE (SP2 Only) Select YES to enable Setpoint 2 and access the setup parameters. If NO is selected, the unit returns to SPt SEL and Setpoint 2 is disabled. YES NO NO SP2 Enb SETPOINT ASSIGNMENT SETPOINT PARAMETER AVAILABILITY Select the display to which the Setpoint is assigned. Count A SPn ASN SETPOINT OUTPUT ACTION The parameter selects the action of the Setpoint Output as described in the chart. Boundary output action is not applicable for Counter B assignment. LAtCH SPn ACt Count A Count b rAtE LAtCH t-OUt bOUNd SPT ACTION DESCRIPTION OUTPUT ACTIVATES OUTPUT DEACTIVATES LAtCH Latched Output Mode When Count = Setpoint At Manual Reset (if SPn rSt=YES) t-OUt Timed Output Mode When Count = Setpoint After Setpoint Output Time-Out bOUNd Boundary Mode (Low Acting Type) Boundary Mode (High Acting Type) When Count ≤ Setpoint When Count ≥ Setpoint When Count > Setpoint When Count < Setpoint |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |