14 / 16 page ![]() 14 Sending Serial Commands and Data When sending commands to the meter, a string containing at least one command character must be constructed. A command string consists of a command character, a value identifier, and numerical data (if writing data to the meter) followed by a command terminator character, * or $. Command Chart Register Identification Chart ID Value Description MNEMONIC Applicable Commands Transmit Details (T and V) A Counter A CTA T, V, R 8 digit positive/7 digit negative (with minus sign) B Counter B CTB T, V, R 7 digit, positive only C Rate RTE T 6 digit, positive only D Scale Factor A SFA T, V 6 digit, positive only E Scale Factor B SFB T, V, 6 digit, positive only F Setpoint 1 (Reset Output 1) SP1 T, V, R per setpoint Assignment, same as Counter or Rate G Setpoint 2 (Reset Output 2) SP2 T, V, R per setpoint Assignment, same as Counter or Rate H Counter A Count Load Value CLD T, V 8 digit positive/7 digit negative (with minus sign) Command String Construction The command string must be constructed in a specific sequence. The meter does not respond with an error message to illegal commands. The following procedure details construction of a command string: 1. The first 2 or 3 characters consist of the Node Address Specifier (N) followed by a 1 or 2 character node address number. The node address number of the meter is programmable. If the node address is 0, this command and the node address itself may be omitted. This is the only command that may be used in conjunction with other commands. 2. After the optional address specifier, the next character is the command character. 3. The next character is the register ID. This identifies the register that the command affects. The P command does not require a register ID character. It prints all the active selections chosen in the Print Options menu parameter. 4. If constructing a value change command (writing data), the numeric data is sent next. 5. All command strings must be terminated with the string termination characters * or $. The meter does not begin processing the command string until this character is received. See Command Response Time section for differences in meter response time when using the * and $ terminating characters. Command String Examples: 1. Node address = 17, Write 350 to the Setpoint 1 value String: N17VF350* 2. Node address = 5, Read Counter A, response time of 50 msec min String: N5TA* 3. Node address = 0, Reset Setpoint 1 output String: RF* 4. Node address = 31, Request a Block Print Output, response time of 2 msec min String: N31P$ Transmitting Data to the Meter Numeric data sent to the meter must be limited to transmit details listed in the Register Identification Chart. Leading zeros are ignored. Negative numbers must have a minus sign. The meter ignores any decimal point and conforms the number to the scaled resolution. (For example: The meter’s scaled decimal point position is set for 0.0 and 25 is written to a register. The value of the register is now 2.5. In this case, write a value of 250 to equal 25.0). Note: Since the meter does not issue a reply to value change commands, follow with a transmit value command for readback verification. Receiving Data From The Meter Data is transmitted from the meter in response to either a transmit command (T), a block print request command (P) or a User Input print request. The response from the meter is either a full field transmission or an abbreviated transmission, depending on the selection chosen in Module 5. Full Field Transmission Byte Description 1, 2 2 byte Node Address field [00-99] 3 <SP> (Space) 4-6 3 byte Register Mnemonic field 7-18 12 byte data field; 10 bytes for number, one byte for sign, one byte for decimal point 19 <CR> (carriage return) 20 <LF> (line feed) 21 <SP>* (Space) 22 <CR>* (carriage return) 23 <LF>* (line feed) * These characters only appear in the last line of a block print. The first two characters transmitted are the meter address. If the address assigned is 0, two spaces are substituted. A space follows the meter address field. The next three characters are the register mnemonic, as shown in the Register Identification Chart. The numeric data is transmitted next. The numeric field (bytes 7 to 18) is 12 characters long. When a requested counter or rate value exceeds the meter’s display limits, an * (used as an overflow character) replaces a space in byte 7. Byte 8 is always a space. The remaining ten positions of this field consist of a minus sign (for negative values), a floating decimal point (if applicable), and eight positions for the requested value. The data within bytes 9 to 18 is right-aligned with leading spaces for any unfilled positions. The end of the response string is terminated with a <CR> and <LF>. After the last line of a block print, an extra <SP>, <CR> and <LF> are added to provide separation between the print blocks. Initiates a block print output. Registers in the print block are selected in Print Options. Block Print Request (read) P Reset a count value or setpoint output. Must be followed by a register ID character Reset R Write to register of the meter. Must be followed by a register ID character and numeric data. Value Change (write) V Read a register from the meter. Must be followed by a register ID character. Transmit Value (read) T Address a specific meter. Must be followed by one or two digit node address. Not required when node address = 0. Node (meter) Address Specifier N Notes Description Command Copy Procedure: 1. Connect the master and receiver using the appropriate copy cable. 2. Apply power to the meters. The receiving meter must be operating in the normal display mode (not programming mode). 3. On the master meter, enter programming mode and proceed to the Copy Program Settings parameter in Module 5. Select YES to begin copying. 4. During the copy process (~ 2 sec.), the master meter displays an upload message (UP-LOAd) while the receiver displays a download message (dn-LOAd). This indicates successful communication between the master and receiver. If the receiver message is not displayed, be sure the proper cable is connected. 5. When copying is complete, the receiver displays the power-up sequence and returns to normal operating mode, programmed with all the same settings as the master meter. The master remains at the COPY prompt, ready to connect another receiver for copying. SEL RST UP-LOAd dn-LOAd SEL RST MASTER RECEIVER |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |