CUB5COM2 数据表(PDF) 8 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CUB5COM2 数据表(HTML) 8 Page - Red Lion Controls. Inc |
|
8 / 16 page ![]() 8 6.2 Module 2 - rate Setup paraMeterS (2-rAtE) SEL Rate Decimal Point Rate Enable Rate Scaling Display Value Rate High Update Time Rate Scaling Input Value Rate Low Update Time 2-rAtE RAtE Enb RAtE dP RAtE dSP RAtE INP LO-Udt HI-Udt Pro PARAMETER MENU RATE ENABLE Module 2 is the programming for the rate parameters. For maximum input frequency, Rate Enable should be set to NO when not in use. When set to NO, the remaining rate parameters are not accessible. The rate value is shown with an annunciator of “R” in the Display Mode. This selects the decimal point position for the rate display and any setpoint value assigned to rate. This parameter does not affect rate scaling calculations. RATE DECIMAL POINT 0.00000 0.000 0.0 0.0000 0.00 0 RATE SCALING INPUT VALUE RATE SCALING DISPLAY VALUE Enter the desired Rate Display Value for the Scaling Point.* Enter the corresponding Rate Input Value for the Scaling Point.* 0 to 999999 0.1 to 99999.9 *For value entry instructions, refer to selection/value entry in the Programming The Meter section. USER INPUT ASSIGNMENT The User Input Assignment is only active when Counter B is enabled and the User Input performs a Reset, Inhibit or Store function on one or both counters. USER INPUT FUNCTION MODE DISPLAY No Function NO DESCRIPTION User Input disabled. Program Mode Lock-out Pro Loc rESEt Inhibit Inhibit counting for the selected counter(s). Store StorE Store and Reset Stor-rSt Display Select * d-SELECt d-LEVEL Increase intensity one level for each activation. (backlight version only) rESEt-12 rESEt-2 rESEt-1 Prnt-r5t Print d-COLOr Advance once for each activation both A-b Count b Count A See Programming Mode Access chart. (Module 3) Setpoint 1 and 2 Reset * Setpoint 2 Reset * Setpoint 1 Reset * Print and Reset * Print Request Backlight Color * Edge triggered reset of the selected counter(s) after storing the count. NO USEr INP Count A USEr ASN YES RAtE Enb 001000 RAtE dSP O RAtE dP 01000.0 RAtE INP YES NO Reset Setpoint 1 and 2 outputs Reset Setpoint 2 output Reset Setpoint 1 output Same as Print Request followed by a momentary reset of the selected counter(s). Change backlight color with each activation (backlight version only) Inhibit Maintained Reset Freeze display of selected counter(s) while allowing counts to accumulate internally. Display Intensity Level * Serial transmit of the active parameters selected in the Print Options (Module 5) SCALING FOR COUNT INDICATION The CUB5’s scale factor is factory set to 1, to provide one count on the display for each pulse that is input to the unit. In many applications, there will not be a one-to-one correspondence between input pulses and display units. Therefore, it is necessary for the CUB5 to scale or multiply the input pulses by a scale factor to achieve the desired display units (feet, meters, gallons, etc.) The Count Scale Factor Value can range from 00.0001 to 99.9999. It is important to note that the precision of a counter application cannot be improved by using a scale factor greater than one. To accomplish greater precision, more pulse information must be generated per measuring unit. The following formula is used to calculate the scale factor. Scale Factor = Desired Display Units x Decimal Point Position Number of Pulses WHERE: Desired Display Units: Count display units acquired after pulses that occurred. Number of Pulses: Number of pulses required to achieve the desired display units. Decimal Point Position: 0 = 1 0.0 = 10 0.00 = 100 0.000 = 1000 0.0000 = 10000 0.00000 = 100000 EXAMPLE: The counter display is used to indicate the total number of feet used in a process. It is necessary to know the number of pulses for the desired units to be displayed. The decimal point is selected to show the resolution in hundredths. Scale Factor = Desired Display Units x Decimal Point Position Number of Pulses Given that 128 pulses are equal to 1 foot, display total feet with a one- hundredth resolution. Scale Factor = 1.00 x 100 128 Scale Factor = 0.007812 x 100 Scale Factor = 0.7812 Level active reset of the selected counter(s). Note: * indicates Edge Triggered function. Other functions are Level Active (maintained) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |