TPS7A0233DBVR 数据表(PDF) 25 Page - Texas Instruments

Click here to check the latest version.
部件名 TPS7A0233DBVR
功能描述  TPS7A02 Nanopower IQ, 25-nA, 200-mA, Low-Dropout Voltage Regulator With Fast Transient Response
PDF  43 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  TI [Texas Instruments]
网页  http://www.ti.com
标志 TI - Texas Instruments

TPS7A0233DBVR 数据表(HTML) 25 Page - Texas Instruments

Back Button TPS7A0233DBVR Datasheet HTML 21Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 22Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 23Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 24Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 25Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 26Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 27Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 28Page - Texas Instruments TPS7A0233DBVR Datasheet HTML 29Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 43 page
background image
25
TPS7A02
www.ti.com
SBVS277B – JULY 2019 – REVISED MARCH 2020
Submit Documentation Feedback
Copyright © 2019–2020, Texas Instruments Incorporated
Application Information (continued)
The maximum power dissipation determines the maximum allowable junction temperature (TJ) for the device.
According to Equation 3, power dissipation and junction temperature are most often related by the junction-to-
ambient thermal resistance (RθJA) of the combined PCB and device package and the temperature of the ambient
air (TA). Equation 4 rearranges Equation 3 for output current.
TJ = TA + (RθJA × PD)
(3)
IOUT = (TJ – TA) / [RθJA × (VIN – VOUT)]
(4)
Unfortunately, this thermal resistance (RθJA) is highly dependent on the heat-spreading capability built into the
particular PCB design, and therefore varies according to the total copper area, copper weight, and location of the
planes. The RθJA recorded in the Thermal Information table is determined by the JEDEC standard, PCB, and
copper-spreading area, and is only used as a relative measure of package thermal performance. For a well-
designed thermal layout, RθJA is actually the sum of the X2SON package junction-to-case (bottom) thermal
resistance (RθJC(bot)) plus the thermal resistance contribution by the PCB copper.
8.1.5.1 Estimating Junction Temperature
The JEDEC standard now recommends the use of psi (Ψ) thermal metrics to estimate the junction temperatures
of the LDO when in-circuit on a typical PCB board application. These metrics are not strictly speaking thermal
resistances, but rather offer practical and relative means of estimating junction temperatures. These psi metrics
are determined to be significantly independent of the copper-spreading area. The key thermal metrics (ΨJT and
ΨJB) are used in accordance with Equation 5 and are given in the Thermal Information table.
ΨJT : TJ = TT + ΨJT × PD and ΨJB : TJ = TB + ΨJB × PD
where:
PD is the power dissipated as explained in Equation 2
TT is the temperature at the center-top of the device package, and
TB is the PCB surface temperature measured 1 mm from the device package and centered on the package
edge
(5)
8.1.5.2 Recommended Area for Continuous Operation
The operational area of an LDO is limited by the dropout voltage, output current, junction temperature, and input
voltage. The recommended area for continuous operation for a linear regulator is given in Figure 60 and can be
separated into the following parts:
Dropout voltage limits the minimum differential voltage between the input and the output (VIN – VOUT) at a
given output current level. See the Dropout Operation section for more details.
The rated output currents limits the maximum recommended output current level. Exceeding this rating
causes the device to fall out of specification.
The rated junction temperature limits the maximum junction temperature of the device. Exceeding this rating
causes the device to fall out of specification and reduces long-term reliability.
The shape of the slope is given by Equation 4. The slope is nonlinear because the maximum rated
junction temperature of the LDO is controlled by the power dissipation across the LDO; thus when VIN
VOUT increases the output current must decrease.
The rated input voltage range governs both the minimum and maximum of VIN – VOUT.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com