| 数据搜索系统,热门电子元器件搜索 |
|
ADR4520ARZ-R7 数据表(PDF) 37 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADR4520ARZ-R7 数据表(HTML) 37 Page - Analog Devices |
|
37 / 40 page ![]() Data Sheet ADR4520/ADR4525/ADR4530/ADR4533/ADR4540/ADR4550 Rev. D | Page 37 of 40 –4 –2 0 2 4 6 8 10 12 OUTPUT VOLTAGE HYSTERESIS (ppm) 0 5 10 15 20 25 30 35 40 45 27 UNITS x 3 CYCLES HALF CYCLE = 25°C, 70°C, 25°C FULL CYCLE = 25°C, 70°C, 25°C, 0°C, 25°C HALF CYCLE FULL CYCLE Figure 118. D Grade Histogram Showing the Temperature Hysteresis of the Output Voltage (0°C to 70°C) Measuring thermal hysteresis over the full operating temperature range is not reflective of a typical operating environment in most applications. Instead, smaller temperature variations are more normal. The ADR4520/ADR4525/ADR4530/ADR4533/ ADR4540/ADR4550 were tested over 20 different temperature cycles of increasing magnitude, centered at +25°C, starting with +25°C ± 5°C and going up to the full operating temperature range of −40°C to +125°C. The results are shown in Figure 119. For a temperature delta of 100°C (that is, +25°C ± 50°C) the thermal hysteresis is less than 20 ppm for both the full cycle and the half cycle. Above this range, the thermal hysteresis increases significantly. These results show that the standard specification, which covers the full operating temperature range, is close to the worst case performance. 0 20 40 60 80 100 120 140 160 –40 –20 0 20 40 60 80 100 TEMPERATURE DELTA (°C) HALF LOOP FULL LOOP Figure 119. Thermal Hysteresis for Increasing Temperature Range HUMIDITY SENSITIVITY The ADR4520/ADR4525/ADR4530/ADR4533/ADR4540/ ADR4550 is packaged in a SOIC plastic package and has a moisture sensitivity level of MSL-1, per the JEDEC standard. However, moisture absorption from the air into the package changes the internal mechanical stresses on the die causing shifts in the output voltage. Figure 120 shows the effects of a step change in relative humidity on the output voltage over time. The humidity chamber is maintained at an ambient temperature of +25°C, while the relative humidity undergoes a step change from 20% to 80% at time zero. The relative humidity is maintained at 80% for the duration of the testing. Note that the output voltage shifts quickly compared to the overall settling time, following the step change in relative humidity. Figure 121 shows the effects of 10% increases in relative humidity from 30% to 70% and back to 30%. Note that after the relative humidity returns to 30%, the output voltage is settling back to its starting point. 0 100 200 300 400 500 600 ELAPSED TIME (Hours) –400 –300 –200 –100 0 100 200 300 400 SAMPLE 1 SAMPLE 2 SAMPLE 3 27 UNITS TA = 25°C RELATIVE HUMIDITY STEP FROM 20% TO 80% Figure 120. Change in Output Voltage vs. Time After Humidity Step Change (20% to 80% Relative Humidity) 0 100 200 300 400 500 600 ELAPSED TIME (Hours) –200 –150 –100 –50 0 50 100 150 200 SAMPLE 1 SAMPLE 2 SAMPLE 3 27 UNITS TA = 25°C RELATIVE HUMIDITY STEP FROM 30% TO 70% TO 30%, 10% STEPS Figure 121. Change in Output Voltage vs. Time for 10% Humidity Steps (30% to 70% to 30% Relative Humidity in 10% Steps) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |