| 数据搜索系统,热门电子元器件搜索 |
|
A22Z-R 数据表(PDF) 12 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
A22Z-R 数据表(HTML) 12 Page - Omron Electronics LLC |
|
12 / 52 page ![]() A22NE-PD 12 Safety Precautions Be sure to read the precautions for All PushButton Switches in the website at: http://www.ia.omron.com/. Indication and Meaning for Safe Use Do not perform wiring with power supplied to the Switch/ Indicator. Do not touch the terminals or other charged parts while power is being supplied. Doing so may result in electric shock. • Make sure the Operation Unit and the Switch Unit are properly assembled. <Assembling the Operation Unit and Switch Unit> (1) Assembling the Operation Unit and Switch Unit Align the TOP indication (the mark ) on the Operation Unit with the TOP indication on the Switch Unit, and insert the Operation Unit while keeping the bottom A pressed. (2) Locking the lock lever With a screwdriver inserted in the lock hole of the lock lever, bring the screwdriver in contact with the convex part of the case, and turn the lock lever until a clicking sound is heard. • When transition wiring is performed, make sure the switching current inside the Switch and the current based on the transition wiring is below the rated current of the Switch. If a current value higher than the rated current flows, it could result in emission of heat, or damage and deformation of the Switch, which could cause fire and locking of the contact, and thus a loss of safety. • Do not disassemble or modify the Switch/Indicator under any circumstances. • Doing so may prevent the Switch/Indicator from functioning to its full capability. Do not drop the Switch/Indicator. Do not apply pressure that may deform or alter the Switch/Indicator. • The durability of the Switch varies considerably depending on the switching conditions. Always test the Switch/Indicator under actual working conditions before application and use the Switch/Indicator only for the number of switching operations allowed. • Do not allow the load voltage and current to exceed the rated value. This may damage or burn out the Switch/Indicator. • Do not use the Switch/Indicator in locations where explosive or flammable gases or liquid may be present or scattered. The electric ark or the heat caused by switching contacts may cause a fire or explosion. • Do not use the Switch/Indicator in locations where toxic gases, such as H2S, SO2, NH3, HNO3, and Cl2, may be present, or in locations subject to high temperature or humidity. Doing so may damage the Switch/Indicator due to contact failure or corrosion. • Do not use the Switch/Indicator submersed in oil or water, or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering and damaging the Switch/ Indicator. • Do not use or keep the Switch/Indicator under the following conditions: • Subject to severe temperature changes. • Subject to high humidity or condensation. • Subject to severe vibration or shock. • Where direct rays of the sun strike. • Where sea breeze may be present. • Make sure that a rubber washer is present between the Operation Unit and the panel. In models with IP69K, make sure the rubber bush of the Operation Unit is properly attached. Otherwise, the specifications of the protective structure may not be satisfied. • Do not apply excessive force to the Switch or wirings. Damage or deformation of the Switch Unit could result in an improper contact or a loss of safety. • Use an appropriate wiring and crimp terminals (hereinafter, called ferrule terminals). • Exercise caution to avoid wiring errors when connecting the terminals. • To prevent wiring materials from smoking or ignition, confirm wire ratings and use the wiring materials given in the following table. Use wiring crimp terminals and ferrule terminals of the specified size. Warning Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Additionally there may be significant property damage. Precautions for Safe Use Comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing to use the product safely and prevent its malfunctioning or an adverse effect on its performance or functions. WARNING Precautions for Safe Use Mark (1) (2) (1) (2) Operation Unit Switch Unit TOP indication Locked position Release position Lock Hole of Lock Lever Convex Part Bottom A <Lock lever position> BD When the lock lever is at the released position in this Switch, the NO and NC contact operation is reversed. Set the lock lever to the locked position when us- ing the Switch. Wire Type Wire material Recommended Wire Wire coating peeling amount Solid wire/ Stranded Wire Copper 0.25 to 1.5 mm2 AWG 24 to 16 Ferrules used: 10 to 12 mm (Varies depending on the recommended ferrule conductor length) Ferrules not used: 8 mm |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |