27 / 56 page ![]() DocID026356 Rev 3 27/56 L9780 Diagnostic 55 If INRC pin is below the corresponding voltage threshold reported in Table 13, a possible short to ground condition is detected. Possible short to ground condition is confirmed by the logic (and reported in the SPI output register) only if the duration of the fault is greater than a filter time, defined as a multiple of the clock period; in other words, when the possible sensor short to ground condition is detected, a logic counter starts and when the count reaches the value defined inTable 17, the fault condition is considered validated. This counter is reset when the possible short to ground fault is cleared and after every power on reset. Actions Once the INRC short to ground fault is validated (the duration of possible fault is greater than the filter time) the following action is taken: 1. Set the STGRC bit in the SPI output register. This action remains valid until cleared by the user. 5.3 SNS pin short to ground The device is able to detect and take actions when a short to ground condition happens on SNS pin. If SNS pin is in the range SNS_NTH < SNS < SNS_PTH (SNS_NTH, SNS_PTH thresholds values reported in Table 13), a possible short to ground condition is detected. Possible short to ground condition is confirmed by the logic (and reported in the SPI output register) only if the duration of the fault is greater than a filter time, defined as a multiple of the clock period; in other words, when the possible sensor short to ground condition is detected a logic counter starts and when the count reaches the value defined in Table 17, the fault condition is considered validated. This counter is reset when the possible short to ground fault is cleared and after every power on reset. Actions Once the SNS short to ground fault is validated (the duration of possible fault is greater than the filter time) the following action is taken: 1. Set the STGSNS bit in the SPI output register. This action remains valid until cleared by the user. Application note When the regulation loop is approaching the condition =1, that in terms of electrical parameters means to have 450 mV as output of the reference cell (applied on INRC pin), the output current of the VCCS is very small so the voltage of SNS is near to GND. This does not flag a fault condition but the STGSNS bit in the SPI output register is expected to be set. 5.4 Heater diagnostic The device is able to detect and take actions when a fault condition happens on external heater FET, connected to the device through HG and HD pins. Detected fault conditions are: heater short to battery, heater short to ground, heater open circuit. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |