| 数据搜索系统,热门电子元器件搜索 |
|
RAMK060 数据表(PDF) 4 Page - Vishay Siliconix |
|
|
|||||||||||||||||||||||||||||
RAMK060 数据表(HTML) 4 Page - Vishay Siliconix |
|
4 / 15 page ![]() RAMK060 www.vishay.com Vishay MCB Revision: 03-May-2022 4 Document Number: 32579 For technical questions, contact: mcbprecisionpot@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 SELF-MONITORING All frame includes 3 status bits. These 3 status bits form a 3 bits word. 3 BITS STATUS WORD BIT A1 BIT A2 BIT A3 DECIMAL VALUE LED STATUS INFORMATION ACTION PRIORITY LEVEL MSB LSB Normal operation 0 0 0 0 Green Frame without error or warning. No action required. - Temperature overflow 01 1 3 Red This error is set if the temperature of the sensor is superior to +85 °C or inferior to -40 °C. This information is sent until temperature is over range. Set the environmental temperature between -40 °C to +85 °C . 1 (highest) Mechanical mounting error 00 1 1 Red This error is set when the mechanical tolerances of the airgap parameter are out of range. This information is sent until power supply turns off. The mechanical mounting must be adjusted. 2 Cells default 0 1 0 2 Red This error occurs when a magnetic cell is temporary or completely out of order. This error is sent at each concerned frame. Check the sensor integrity. 3 Need self-calibration 10 0 4 Orange To get the best performances, a self-calibration is required. This information is available until power supply turns off. The self-calibration shall be start. 4 Self-calibration error 10 1 5 Orange This warning occurs when the self-calibration is not ended correctly. The factory settings are restored. This information is available until power supply turns off. The self-calibration shall be restarted. 5 Multi-turn counter error 11 0 6 Green This warning occurs when at the power on the sensor has detected an excessive displacement during the power off. This warning and the multi-turns counter are reset at the next power on. No action required. 6 Internal angle correction 11 1 7 Orange stealthily This warning occurs when the sensor has performed an internal correction error. This warning is sent at each concerned frame. It is advisable to adjust the mechanical assembly or to perform a self- calibration. 7 (lowest) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |