| 数据搜索系统,热门电子元器件搜索 |
|
H7CC-R11 数据表(PDF) 34 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CC-R11 数据表(HTML) 34 Page - Omron Electronics LLC |
|
34 / 66 page ![]() 34 H7CC-A @ tachometer Explanation of Functions Tachometer Operation Tachometer Input Mode (tinm) Set the count input mode to one of the following: 1 input (F1), 2 inputs (F2), error (F3), absolute ratio (F4), or error ratio (F5). Tachometer Output Mode (totm) Set the output method for control output based on the comparison value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI-HI), and lower limit (LO-LO) can be set. (For details on the output modes, refer to Output Mode Settings and Operation on page 38.) Counting Speed (cnts) Set the maximum counting speed (30 Hz/10 kHz) for CP1 input. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. Decimal Point Position (dp) Decide the decimal point position for the measurement value, OUT1 set value, and OUT2 set value. Prescale Value (pscl) It is possible to display the rate of rotation or the speed of a device or machine to which the H7CC is mounted by converting input pulses to a desired unit. If this prescaling function is not used, the input frequency (Hz) will be displayed. It is also possible to specify time (seconds) as the display value. Refer to Display Unit on page 35 for details. The relationship between display and input is determined by the following equation. Set the prescale value according to the unit to be displayed. Displayed value = f × α f: Input pulse frequency (number of pulses in 1 second) α: Prescale value (1) Displaying Rotation Rate N: Number of pulses per revolution Example: To display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@.@ rpm: 1. Set the decimal point position to 1 decimal places. 2. Using the formula, set the prescale value ( α) to 1/N × 60 = 60/5 = 12. (2) Displaying Speed N: Number of pulses per revolution d: Diameter of rotating body (m) πd: Circumference (m) • Observe the following points when setting a prescale value. Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). If the set value is set to a value greater than this, output will not turn ON. • Output will turn ON, however, if a present value overflow occurs (FFFFFF}. Averaging Method (avgt) A simple average or moving average can be selected for the averaging. With the moving average method, the average of the measurement values is displayed each sampling cycle, in contrast to a simple average, with which the the average of the set number of samples is displayed. Number of Averaging Times (avgn) Flickering display and output chattering can be prevented using average processing. Average processing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, 8 times, or 16 times. The measurement cycle will be equal to the sampling cycle multiplied by the average processing setting (i.e., the number of times). Average processing enables stable displays even for fluctuating input signals. Set the optimum number of times for the application. Auto-zero Time (auto0) The display can be force-set to 0 if there is no pulse for a certain period of time. This time is called the auto-zero time. Set the auto-zero time to a time slightly longer than the estimated interval between input pulses. Accurate measurement is not possible if the auto-zero time is set to a time shorter than the input pulse cycle. Setting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turning ON. The auto-zero time is not applied to pulse width measurements. Input mode Input Internal processing Application 1 input Count 1 None Operation with only one input. 2 inputs Counts 1 and 2 None Operation with two independent inputs. Error Counts 1 and 2 Count 1 input − Count 2 input Measuring the difference between two inputs (error in number of revolutions). Absolute ratio Counts 1 and 2 Count 1 input ÷ Count 2 input Measuring the ratio of two inputs (ratio of number of revolutions). Error ratio Counts 1 and 2 (Count 1 input − Count 2 input) ÷ Count 2 input Measuring the ratio of error for two inputs (measuring the error ratio of number of revolutions). Display unit Prescale value ( α) rpm 1/N × 60 rps 1/N Display unit Prescale value ( α) m/min πd × 1/N × 60 m/s πd × 1/N d: Diameter of rotating body (m) Note: If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |