Back Button ADIS16250/PCBZ Datasheet HTML 12Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 13Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 14Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 15Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 16Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 17Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 18Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 19Page - Analog Devices ADIS16250/PCBZ Datasheet HTML 20Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 19 / 20 page
background image
ADIS16250
Rev. 0 | Page 19 of 20
Alarms
The ADIS16250 provides two independent alarm options for
event detection. Event detections occur when output register
data meets the configured conditions. Configuration options are:
All output data registers are available for monitoring
as the source data
The source data can be filtered or unfiltered
Comparisons can be static or dynamic (rate of change)
The threshold levels and times are configurable
Comparison can be greater than or less than
The ALM_MAG1 register and the ALM_MAG2 register both
establish the threshold level for detecting events. They take on the
format of the source data and provide a bit for establishing the
greater than/less than comparison direction. When making
dynamic comparisons, the ALM_SMPL1 register and the
ALM_SMPL2 register establish the number of averages taken for
the source data as a reference for comparison. In this configuration,
each subsequent source data sample is subtracted from the previous
one, establishing an instantaneous delta. The ALM_CTRL register
controls the source data selection, static/dynamic selection, filtering
selection, and digital I/O usage for the alarms.
The rate of change calculation is
)
?
or
(
MSB
ALM_MAG1/2
to
according
with
Compare
alarm
change
of
Rate
)
(
)
1
(
1
with
compared
be
factor to
ALM_MAG1/2
in
comparison
for
magnitude
data
output
sampled
)
(
2
ALM_SMPL1/
in
samples
of
number
DS
N
1
n
<
>
+
=
=
=
=
=
=
C
C
DS
C
C
C
C
DS
M
Y
n
y
n
y
N
Y
M
Y
M
n
y
N
Table 31. ALM_MAG1 Register Definition
Address
Default
Format
Access
0x21, 0x20
0x0000
N/A
R/W
Table 32. ALM_MAG1 Bit Designations
Bit
Description
15
Comparison polarity: 1 = greater than, 0 = less than
14
Not used
13:0
Data bits: format matches source data format
Table 33. ALM_SMPL1 Register Definition
Address
Default
Format
Access
0x25, 0x24
0x0000
Binary
R/W
Table 34. ALM_SMPL1 Bit Designations
Bit
Description
15:8
Not used
7:0
Data bits
Table 35. ALM_MAG2 Register Definition
Address
Default
Format
Access
0x23, 0x22
0x0000
N/A
R/W
Table 36. ALM_MAG2 Bit Designations
Bit
Description
15
Comparison polarity: 1 = greater than, 0 = less than
14
Not used
13:0
Data bits: format matches source data format
Table 37. ALM_SMPL2 Register Definition
Address
Default
Format
Access
0x27, 0x26
0x0000
Binary
R/W
Table 38. ALM_SMPL2 Bit Designations
Bit
Description
15:8
Not used
7:0
Data bits
Table 39. ALM_CTRL Register Definition
Address
Default
Format
Access
0x29, 0x28
0x0000
N/A
R/W
Table 40. ALM_CTRL Bit Designations
Bit
Value
Description
15
Rate of change (ROC) enable for alarm 2
1 = rate of change, 0 = static level
14:12
Alarm 2 source selection
000
Disable
001
Power supply output
010
Gyroscope output
011
Inactive
100
Inactive
101
Auxiliary ADC output
110
Temperature sensor output
111
Inactive
11
Rate of change (ROC) enable for alarm 1
1 = rate of change, 0 = static level
10:8
Alarm 1 source selection
000
Disable
001
Power supply output
010
Gyroscope output
011
Inactive
100
Inactive
101
Auxiliary ADC output
110
Temperature sensor output
111
Inactive
7:5
Not used
4
Filtered data comparison
1 = filtered data, 0 = unfiltered data
3
Not used
2
Alarm output enable
1 = enabled, 0 = disabled
1
Alarm output polarity
1 = active high, 0 = active low
0
Alarm output line select
1 = DIO1, 0 = DIO0



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com