| 数据搜索系统,热门电子元器件搜索 |
|
NA-RTSM 数据表(PDF) 29 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
NA-RTSM 数据表(HTML) 29 Page - Omron Electronics LLC |
|
29 / 36 page ![]() NA series 29 General Specifications *1. The ambient operating temperature is subject to the following restrictions, depending on the mounting angle. • The ambient operating temperature is 0° to 40°C when the mounting angle is 0° or more and less than 45° to the horizontal. • The ambient operating temperature is 0° to 50°C when the mounting angle is 45° or more and 90° or less to the horizontal. • The ambient operating temperature is 0° to 50°C when the mounting angle is 90° or more and 135° or less to the horizontal. *2. Use the Programmable Terminal within the following temperature and humidity ranges. *3. Store the Programmable Terminal within the following temperature and humidity ranges. *4. When the NA-@WATW01 High-pressure Waterproof Attachment is used, the panel thickness is between 1.6 to 4.5 mm. *5. Check with your OMRON representative or refer to the following OMRON website for the latest information on the applicable standards for each model: www.ia.omron.com. *6. Use power supply Class 2 to conform to UL Standards. *7. Use the NA-@WATW01 High-pressure Waterproof Attachment (sold separately) to conform to UL Type 4X. Note: 1. For information on the product whose model number does not end with -V1, refer to the Programmable Terminal NA Series Datasheet (Cat. No. V413). Item Specification NA5-15W NA5-12W NA5-9W NA5-7W Rated supply voltage 24 VDC Allowable power supply voltage range 19.2 to 28.8 VDC (24 VDC ±20%) Allowable momentary power interruption time Operation for momentary power interruption is not specified. Power consumption 29 W max. 25 W max. 23 W max. 19 W max. Ambient operating temperature 0 to 50 °C *1 *2 Ambient storage temperature −20 to +60°C *3 Ambient operating humidity 10 to 90% *2 Must be no condensation. Atmosphere Must be free from corrosive gases. Pollution degree 2 or less: Meets IEC 61010-2-201. Noise immunity 2 kV on power supply line (Conforms to IEC 61000-4-4.) Vibration resistance (during operation) Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5 mm half amplitude and 8.4 to 150 Hz with 9.8 m/s2 for 100 minutes each in X,Y, and Z directions (Time coefficient of 10 minutes × coefficient factor of 10 = total time of 100 min.) Shock resistance (during operation) Conforms to IEC 60028-2-27. 147 m/s2 3 times each in X, Y, and Z directions Dimensions 420 × 291 × 69 mm (W × H × D) 340 × 244 × 69 mm (W × H × D) 290 × 190 × 69 mm (W × H × D) 236 × 165 × 69 mm (W × H × D) Panel cutout dimensions 392 × 268 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4 310 × 221 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4 261 × 166 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4 197 × 141 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4 Weight 3.2 kg max. 2.4 kg max. 1.8 kg max. 1.4 kg max. Degree of protection Front-panel controls: IP65 oil-proof type, UL Type 4X (at initial state) To reinstall the NA Unit in a panel, contact your OMRON representative for replacement of the rubber packing. Battery life Battery life: 5 years at 25 °C The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up by a super capacitor for 5 minutes after removing the old battery. (This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.) International standards *5 UL61010-2-201/CSA C22.2 NO.61010-2-201:14 *6 EMC Directive (2004/108/EC) EN 61131-2:2007 Shipbuilding standards LR, DNV, and NK IP65 oil-proof, UL Type 4X *7(front panel only) UL 121201, 9th Edition/CSA C22.2 NO.213-2017 EAC IEC61131-2:2007 KC Standards KN61131-2 2018 RCM EN61000-6-4:2007+A1:2011 +1 0 +1 0 +1 0 +1 0 +1 0 +1 0 +0.5 0 +0.5 0 50 °C 50 °C 40 °C 40 °C 50 °C 90 ° to 135° 45 ° to 90° 0 ° to 45° 50 °C 50 °C Temperature [ °C] 0 10 20 30 40 50 60 70 80 90 100 -10 0 10 20 30 40 50 60 Operating temperature- humidity range Temperature [ °C] 0 10 20 30 40 50 60 70 80 90 100 -20 -10 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 80 90 100 Storage temperature- humidity range |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |