| 数据搜索系统,热门电子元器件搜索 |
|
DSPIC30F 数据表(PDF) 142 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
DSPIC30F 数据表(HTML) 142 Page - Microchip Technology |
|
142 / 220 page ![]() dsPIC30F5011/5013 DS70116C-page 140 Preliminary 2004 Microchip Technology Inc. 20.2.7 FAIL-SAFE CLOCK MONITOR The Fail-Safe Clock Monitor (FSCM) allows the device to continue to operate even in the event of an oscillator failure. The FSCM function is enabled by appropriately programming the FCKSM configuration bits (clock switch and monitor selection bits) in the FOSC Device Configuration register. If the FSCM function is enabled, the LPRC internal oscillator will run at all times (except during Sleep mode) and will not be subject to control by the SWDTEN bit. In the event of an oscillator failure, the FSCM will gen- erate a clock failure trap event and will switch the sys- tem clock over to the FRC oscillator. The user will then have the option to either attempt to restart the oscillator or execute a controlled shutdown. The user may decide to treat the trap as a warm Reset by simply loading the Reset address into the oscillator fail trap vector. In this event, the CF (Clock Fail) status bit (OSCCON<3>) is also set whenever a clock failure is recognized. In the event of a clock failure, the WDT is unaffected and continues to run on the LPRC clock. If the oscillator has a very slow start-up time coming out of POR, BOR or Sleep, it is possible that the PWRT timer will expire before the oscillator has started. In such cases, the FSCM will be activated and the FSCM will initiate a clock failure trap, and the COSC<1:0> bits are loaded with FRC oscillator selection. This will effec- tively shut-off the original oscillator that was trying to start. The user may detect this situation and restart the oscillator in the clock fail trap ISR. Upon a clock failure detection, the FSCM module will initiate a clock switch to the FRC oscillator as follows: 1. The COSC bits (OSCCON<13:12>) are loaded with the FRC oscillator selection value. 2. CF bit is set (OSCCON<3>). 3. OSWEN control bit (OSCCON<0>) is cleared. For the purpose of clock switching, the clock sources are sectioned into four groups: 1. Primary 2. Secondary 3. Internal FRC 4. Internal LPRC The user can switch between these functional groups but cannot switch between options within a group. If the primary group is selected, then the choice within the group is always determined by the FPR<3:0> configuration bits. The OSCCON register holds the control and status bits related to clock switching. • COSC<1:0>: Read only status bits always reflect the current oscillator group in effect. • NOSC<1:0>: Control bits which are written to indicate the new oscillator group of choice. - On POR and BOR, COSC<1:0> and NOSC<1:0> are both loaded with the configuration bit values FOS<1:0>. • LOCK: The LOCK status bit indicates a PLL lock. • CF: Read only status bit indicating if a clock fail detect has occurred. • OSWEN: Control bit changes from a ‘0’ to a ‘1’ when a clock transition sequence is initiated. Clearing the OSWEN control bit will abort a clock transition in progress (used for hang-up situations). If configuration bits FCKSM<1:0> = 1x, then the clock switching and Fail-Safe Clock monitoring functions are disabled. This is the default configuration bit setting. If clock switching is disabled, then the FOS<1:0> and FPR<3:0> bits directly control the oscillator selection and the COSC<1:0> bits do not control the clock selec- tion. However, these bits will reflect the clock source selection. 20.2.8 PROTECTION AGAINST ACCIDENTAL WRITES TO OSCCON A write to the OSCCON register is intentionally made difficult because it controls clock switching and clock scaling. To write to the OSCCON low byte, the following code sequence must be executed without any other instructions in between: Byte write is allowed for one instruction cycle. Write the desired value or use bit manipulation instruction. To write to the OSCCON high byte, the following instructions must be executed without any other instructions in between: Byte write is allowed for one instruction cycle. Write the desired value or use bit manipulation instruction. Note: The application should not attempt to switch to a clock of frequency lower than 100 KHz when the fail-safe clock monitor is enabled. If such clock switching is performed, the device may generate an oscillator fail trap and switch to the Fast RC oscillator. Byte Write “0x46” to OSCCON low Byte Write “0x57” to OSCCON low Byte Write “0x78” to OSCCON high Byte Write “0x9A” to OSCCON high |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |