| 数据搜索系统,热门电子元器件搜索 |
|
AD9927BBCZ 数据表(PDF) 58 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9927BBCZ 数据表(HTML) 58 Page - Analog Devices |
|
58 / 100 page ![]() AD9927 Rev. 0 | Page 58 of 100 FIELD COUNTERS The AD9927 contains three field counters (primary, secondary, and mode). When these counters are active, they increment with each VD cycle. The mode counter is the field counter used with the mode register to control the vertical timing signals, which was discussed in the MODE Registers section. The primary and secondary counters are more flexible and are generally used for shuttering signal applications. Both the primary and secondary counters have several modes of operation that are dictated by Address 0x70, including • Normal (single count) • RapidShot (repeating count) • ShotDelay (delayed count) • ShotDelay with RapidShot • Manual exposure • Manual readout • Force to idle The primary counter regulates the expose and read actions by regulating the SUBCK and VSG signals. In addition, if the RapidShot feature is used with the primary counter, the SUBCK and VSG masking automatically repeats as necessary for multiple expose/read cycles. The secondary counter has no effect on the SUBCK or VSG signal. Both counters can be used to regulate the general-purpose signals described in the General-Purpose Outputs (GPOs) section. Table 41. Primary/Secondary Field Counter Registers (Address 0x70, Address 0x71, and Address 0x72) Register Length Description PRIMARY_ACTION 3b 0: idle, no counter action. GPO signals can still be controlled using polarity or GP_PROTOCOL = 1. SECOND_ACTION 3b 1: activate counter. Single cycle of counter from 1 to counter maximum value, and then returns to idle state. 2: RapidShot. After reaching maximum counter value, counter wraps and repeats until reset. 3: ShotTimer: Active single cycle of counter after added delay of N fields (use the corresponding DELAY register). 4: ShotTimer with RapidShot. Same as 2, with added delay of N fields between each repetition. 5: manual exposure. Primary counter stays in exposure until manual readout or reset to idle. This mode keeps the SUBCK and VSG pulses masked indefinitely. 6: manual readout. Primary counter switches to readout (VSG pulses becomes active). 7: force to idle. PRIMARY_MAX 13b Primary counter maximum value. SECOND_MAX 12b Secondary counter maximum value. VDHD_MASK 3b Mask VD/HD during counter operation. PRIMARY_DELAY 13b ShotTimer. Number of fields to delay before the next primary count (exposure) starts. If using ShotTimer with RapidShot, delay value is used between each repeat. PRIMARY_SKIP 1b When using ShotTimer with RapidShot, use primary delay value only before first count (exposure). SECOND_DELAY 13b ShotTimer. Number of fields to delay before the next secondary count starts. If using ShotTimer with RapidShot, delay value is used between each repeat. SECOND_SKIP 1b When using ShotTimer with RapidShot, use secondary delay value only before first count. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |