12 / 31 page ![]() Device Operation (Continued) ANCILLIARY/CONTROL DATA PATH The 10-bit Ancilliary and Control Data Port AD[9:0] serves two functions in the CLC031. Ancilliary data from the Ancilliary Data FIFO is output from this port after its recov- ery from the video data stream. The utilization and flow of ancilliary data from the device is managed by a system of control bits, masks and IDs stored in the control data regis- ters. This port also provides read/write access to contents of the configuration and control registers. The signals RD/WR, ANC/CTRL and A CLK control data flow through the port. Control Data Functions Control data is input to and output from the CLC031 using the lower-order 8 bits AD[7:0] of the Ancilliary/Control Data Port. This control data initializes, monitors and controls op- eration of the CLC031. The upper two bits AD[9:8] of the port function as handshaking signals with the device access- ing the port. When either a control register read or write address is being written to the port, AD[9:8] must be driven as 00b (0XXh, where XX are AD[7:0]). When control data is being written to the port, AD[9:8] must be driven as 11b (3XXh, where XX are AD[7:0]). When control data is being read from the port, the CLC031 will output AD[9:8] as 10b (2XXh, where XX are output data AD[7:0]) and may be ignored by the monitoring system. Note: After either a manual or power-on reset, A CLK must be toggled three (3) times to complete initiallization of the An- cilliary and Control Data Port. The sequence of clock and control signals for reading control data from the ancilliary/control data port is shown in Figure 2. Control data read mode is invoked by making the ANC/ CTRL input low and the RD/WR input high. The 8-bit ad- dress of the control register set to be accessed is input to the port on bits AD[7:0]. To identify the data as an address, AD[9:8] must be driven as 00b. The complete address word will be 0XXh, where 0 is AD[9:8] and XX are AD[7:0]. The address is captured on the rising edge of A CLK. When control data is being read from the port, the CLC031 will output AD[9:8] as 10b (2XXh, where XX are output data AD[7:0]) and may be ignored by the monitoring system. Data being output from the selected register is driven by the port immediately following the rising edge of A CLK or when the address signal is removed. For optimum system timing, the signals driving the address to the port should be removed immediately after the address is clocked into the port and before or simultaneously with the falling edge of A CLK at the end of that address cycle. Output data remains stable until the next rising edge of A CLK and may be written into external devices at any time after the removal of the address signal. This second clock resets the port from drive to receive and readies the port for another access cycle. Example: Read the Full-field Flags via the AD port. 1. Set ANC/CTRL to a logic-low. 2. Set RD/WR to a logic-high. 3. Present 001h to AD[9:0] as the register address. 4. Toggle A CLK. 5. Release the bus driving the AD port. 6. Read the data present on the AD port. The Full-field Flags are bits AD[4:0]. 7. Toggle A CLK to release the AD port. Figure 3 shows the sequence of clock and control signals for writing control data to the ancilliary/control data port. The control data write mode is similar to the read mode. Con- trol data write mode is invoked by making the ANC/CTRL input low and the RD/WR input low. The 8-bit address of the control register set to be accessed is input to the port on bits AD[7:0]. When a control register write address is being written to the port, AD[9:8] must be driven as 00b (0XXh, where XX are AD[7:0]). The address is captured on the rising edge of A CLK. The address data is removed on the falling edge of A CLK. Next, the control data is presented to the port bits AD[7:0] and written into the selected register on the next rising edge of A CLK. When control data is being written to the port, AD[9:8] must be driven as 11b (3XXh, where XX are AD[7:0]). Control data written into the registers may be read out non-destructively in most cases. Example: Setup (without enabling) the TPG Mode via the AD port using the 1125 line, 30 frame, 74.25MHz, interlaced component (SMPTE 274M) colour bars as test pattern. The TPG may be enabled after setup using the Multi-function I/O port or by the control registers. 1. Set ANC/CTRL to a logic-low. 2. Set RD/WR to a logic-low. 3. Present 00Dh to AD[9:0] as the Test 0 register address. 4. Toggle A CLK. 5. Present 027h to AD[9:0] as the register data. 6. Toggle A CLK. www.national.com 12 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |