| 数据搜索系统,热门电子元器件搜索 |
|
AS8579 数据表(PDF) 22 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8579 数据表(HTML) 22 Page - ams AG |
|
22 / 44 page ![]() Document Feedback AS8579 Functional Description Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 21 The 0x90 command allows for I and Q data to be read from the same sensor signal sample by doing a quick read on both I and Q data registers. This command links the I and Q registers together into a 32-bit word. This data is read back using a 40-bit word in this order: command byte, I data word, Q data word. I/Q data matching is guaranteed using the Quick Read command (i.e. – I and Q data will be from a matched sample). The I and Q data registers are reset to 0x00 after reading. Figure 17: SPI Example of Read Sensor ID, Write EDIV and Read EDIV Register ADDR = 0x01 CS SCLK MOSI MISO Read Sensor ID (Sensor ID = 0xA431) Write EDIV (EDIV = 0x00 0x01) Read EDIV (EDIV = 0x00 0x01) DATA1=0x00 DATA2=0x00 cmd* = 0x01 Data1 = 0xA4 Data2 = 0x31 * Sensor repeat command ADDR = 0x30 DATA1=0x00 DATA2=0x01 cmd* = 0x01 Data1 = 0x00 Data2 = 0x00 ADDR = 0x20 DATA1=0x00 DATA2=0x00 cmd* = 0x01 Data1 = 0x00 Data2 = 0x01 CS SCLK MOSI MISO CS SCLK MOSI MISO |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |