| 数据搜索系统,热门电子元器件搜索 |
|
MP8861 数据表(PDF) 24 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP8861 数据表(HTML) 24 Page - Monolithic Power Systems |
|
24 / 37 page ![]() MP8861 – 2.85V - 18V, 6A, SYNCHRONOUS, STEP-DOWN CONVERTER MP8861 Rev. 1.1 www.MonolithicPower.com 24 5/28/2020 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. The bit Retry OVP defines the protection mode when OVP is triggered. When Retry OVP is set to 1, the part enters auto-recovery when OVP is removed. When Retry OVP is set to 0, the part latches off once output OVP occurs, and VIN OVP is triggered until VIN or EN are toggled. The bit Hiccup OCP defines the over-current protection mode. When Hiccup OCP is set to 1, the part enters hiccup mode when OCP and UVP are both triggered. When Hiccup OCP is set to 0, the part enters latch-off when OCP and UVP are both triggered. The lowest bit, Mode, is used for selecting forced PWM or auto-PFM/PWM mode at light load. When Mode is set to 0, auto-PFM/PWM mode is enabled at light load. When Mode is set to 1, forced PWM mode is enabled at light load. NAME BITS DEFAULT DESCRIPTION EN D[7] 1 I2C controlled turn-on or turn-off of the part. When the external EN is low, the converter is off and I2C shuts down. When EN is high, the EN bit takes over. The default EN bit is 1. GO_BIT D[6] 0 Switch bit of the I2C writing authority for the output reference command only. Set GO_BIT = 1 to enable the I2C authority of writing the output reference. When the command is finished, GO_BIT auto-resets to 0 to prevent false operation of the Vref scaling. Voltage scaling examples: 1) Set GO_BIT = 1. 2) Write register 00: set the output reference. 3) Read back the GO_BIT value to see if the output scaling is finished. If GO_BIT = 0, the voltage scaling is done. Otherwise, Vref is still in adjustment. 4) Set GO_BIT = 1 if output voltage scaling is needed a second time. 5) Write register 00: set the output reference. Slew Rate D[5:3] 100 The slew rate during the I2C-controlled voltage changing is defined by three bits. The output voltage changes linearly from the previous voltage to the new set voltage with a slew rate (see below). This helps reduce the inrush current, voltage overshoot, and voltage undershoot greatly. D[5:3] Slew Rate D[5:3] Slew Rate 000 40mV/μs 100 5mV/μs 001 30mV/μs 101 2.5mV/μs 010 20mV/μs 110 1.25mV/μs 011 10mV/μs 111 0.625mV/μs Retry OVP D[2] 1 FB or Vref over-voltage protection mode selection bit. 1 means the part auto- recovers when OVP is removed. 0 means the part latches off once output OVP and VIN OVP are both triggered until VIN or EN is power reset. Hiccup OCP D[1] 1 Over-current protection mode selection. 1 means hiccup mode OCP. 0 means latch-off type OCP. Mode D[0] 0 Set Mode to 0 to enable PFM mode. Set Mode to 1 to disable auto- PFM/PWM mode. The default is auto-PFM/PWM mode for light load. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |