Back Button TSL2569CS Datasheet HTML 21Page - OSRAM GmbH TSL2569CS Datasheet HTML 22Page - OSRAM GmbH TSL2569CS Datasheet HTML 23Page - OSRAM GmbH TSL2569CS Datasheet HTML 24Page - OSRAM GmbH TSL2569CS Datasheet HTML 25Page - OSRAM GmbH TSL2569CS Datasheet HTML 26Page - OSRAM GmbH TSL2569CS Datasheet HTML 27Page - OSRAM GmbH TSL2569CS Datasheet HTML 28Page - OSRAM GmbH TSL2569CS Datasheet HTML 29Page - OSRAM GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 56 page
background image
Page 24
ams Datasheet
Document Feedback
[v1-00] 2016-Apr-12
TSL2568, TSL2569 − Principles of Operation
Control Register (0h)
The Control Register contains two bits and is primarily used to
power the TSL256x device up and down as shown in Figure 29.
Figure 29:
Control Register
Note(s):
1. If a value of 03h is written, the value returned during a read cycle will be 03h. This feature can be used to verify that the device is
communicating properly.
Timing Register (1h)
The Timing Register controls both the integration time and the
gain of the ADC channels. A common set of control bits is
provided that controls both ADC channels. The Timing Register
defaults to 02h at power on.
Figure 30:
Timing Register
Note(s):
1. This field only has meaning when INTEG = 11. It is ignored at all other times.
7
6
5432
10
Resv
Resv
Resv
Resv
Resv
Resv
POWER
Field
Bit
Description
Resv
7:2
Reserved. Write as 0.
POWER
1:0
Power up/power down. By writing a 03h to this register, the device is powered up.
By writing a 00h to this register, the device is powered down.(1)
7
6
5432
10
Resv
GAIN
Manual
Resv
INTEG
Field
Bit
Description
Resv
7:5
Reserved. Write as 0.
GAIN
4
Switches gain between low gain and high gain modes. Writing a 0 selects low gain
(1×); writing a 1 selects high gain (16×).
Manual
3
Manual timing control. Writing a 1 begins an integration cycle. Writing a 0 stops an
integration cycle.(1)
Resv
2
Reserved. Write as 0.
INTEG
1:0
Integrate time. This field selects the integration time for each conversion.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com