15 / 30 page ![]() M41T256Y Operating modes 15/30 2.3 Write mode In this mode the master transmitter transmits to the M41T256Y slave receiver. Bus protocol is shown in Figure 10 on page 15. Following the START condition and slave address, a logic '0' (R/W=0) is placed on the bus and indicates to the addressed device that byte addresses A(0) and A(1) will follow and is to be written to the on-chip address pointer (MSB of address byte A(0) is a “Don’t care”). The data byte to be written to the memory is strobed in next and the internal address pointer is incremented to the next memory location within the RAM on the reception of an acknowledge bit. The M41T256Y slave receiver will send an acknowledge bit to the master transmitter after it has received the slave address (see Figure 7 on page 13) and again after it has received each address byte. Figure 10. Write mode sequence 2.4 Data retention mode With valid VCC applied, the M41T256Y can be accessed as described above with READ or WRITE cycles. Should the supply voltage decay, the M41T256Y will automatically deselect, write protecting itself when VCC falls between VPFD (max) and VPFD (min). This is accomplished by internally inhibiting access to the clock registers. At this time, the reset pin (RST) is driven active and will remain active until VCC returns to nominal levels. When VCC falls below the battery back-up switchover voltage (VSO), power input is switched from the VCC pin to the external battery and the clock registers and SRAM are maintained from the attached battery supply. All outputs become high impedance. On power up, when VCC returns to a nominal value, write protection continues for tREC. The RST signal also remains active during this time (see Figure 14 on page 25). For a further more detailed review of lifetime calculations, please see Application Note AN1012. AI04761 BUS ACTIVITY: S P SDA LINE BUS ACTIVITY: MASTER DATA n DATA n+X BYTE ADDRESS (0) SLAVE ADDRESS BYTE ADDRESS (1) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |