3 / 36 page ![]() 3 general meTer speCifiCaTiOns 1. DISPLAY: 5 digit, 0.56" (14.2 mm) red sunlight readable or standard green LEDs, (-19999 to 99999) 2. POWER: AC Versions: AC Power: 85 to 250 VAC, 50/60 Hz, 15 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. DC Versions (Not available on PAXH): DC Power: 11 to 36 VDC, 11 W (derate operating temperature to 40° C if operating <15 VDC and three option cards are installed) AC Power: 24 VAC, ± 10%, 50/60 Hz, 15 VA Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working). 3. ANNUNCIATORS: MAX - maximum readout selected MIN - minimum readout selected TOT - totalizer readout selected, flashes when total overflows SP1 - setpoint alarm 1 is active SP2 - setpoint alarm 2 is active SP3 - setpoint alarm 3 is active SP4 - setpoint alarm 4 is active Units Label - optional units label backlight 4. KEYPAD: 3 programmable function keys, 5 keys total 5. A/D CONVERTER: 16 bit resolution 6. UPDATE RATES: A/D conversion rate: 20 readings/sec. Step response: 200 msec. max. to within 99% of final readout value (digital filter and internal zero correction disabled) 700 msec. max. (digital filter disabled, internal zero correction enabled) PAXH Only: 1 sec max. to within 99% of final readout value (digital filter disabled) Display update rate: 1 to 20 updates/sec. Setpoint output on/off delay time: 0 to 3275 sec. Analog output update rate: 0 to 10 sec Max./Min. capture delay time: 0 to 3275 sec. 7. DISPLAY MESSAGES: “OLOL” - Appears when measurement exceeds + signal range. “ULUL” - Appears when measurement exceeds - signal range PAXT: “SHrt” - Appears when shorted sensor is detected. (RTD only) PAXT: “OPEN” - Appears when open sensor is detected. “. . . .” - Appears when display values exceed + display range. “- . . .” - Appears when display values exceed - display range. “E . . .” - Appears when Totalizer exceeds 9 digits. “h . . .” - Denotes the high order display of the Totalizer. 8. INPUT CAPABILITIES: See specific product specifications, pages 4-6 9. EXCITATION POWER: See specific product specifications, pages 4-6 10. LOW FREQUENCY NOISE REJECTION: (Does not apply to PAXH) Normal Mode: > 60 dB @ 50 or 60 Hz ±1%, digital filter off Common Mode: >100 dB, DC to 120 Hz 11. USER INPUTS: Three programmable user inputs Max. Continuous Input: 30 VDC Isolation To Sensor Input Common: Not isolated. (Not PAXH) PAXH: Isolation to Sensor Input Common: 1400 Vrms for 1 min. Working Voltage: 125 V Response Time: 50 msec. max. Logic State: Jumper selectable for sink/source logic INPUT STATE SINKING INPUTS 22 KΩ pull-up to +5 V SOURCING INPUTS 22 KΩ pull-down Active VIN < 0.9 VDC VIN > 3.6 VDC Inactive VIN > 3.6 VDC VIN < 0.9 VDC 12. TOTALIZER: Function: Time Base: second, minute, hour, or day Batch: Can accumulate (gate) input display from a user input Time Accuracy: 0.01% typical Decimal Point: 0 to 0.0000 Scale Factor: 0.001 to 65.000 Low Signal Cut-out: -19,999 to 99,999 Total: 9 digits, display alternates between high order and low order readouts 13. CUSTOM LINEARIZATION: Data Point Pairs: Selectable from 2 to 16 Display Range: -19,999 to 99,999 Decimal Point: 0 to 0.0000 PAXT: Ice Point Compensation: user value (0.00 to 650.00 µV/°C) 14. MEMORY: Nonvolatile E2PROM retains all programmable parameters and display values. 15. ENVIRONMENTAL CONDITIONS: Operating Temperature Range: 0 to 50°C (0 to 45°C with all three option cards installed) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g. Shock to IEC 68-2-27: Operational 25 g (10 g relay). Storage Temperature Range: -40 to 60°C Operating and Storage Humidity: 0 to 85% max. RH non-condensing Altitude: Up to 2000 meters 16. CERTIFICATIONS AND COMPLIANCES: CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A Safety requirements for electrical equipment for measurement control, and laboratory use: EN 61010-1: General Requirements EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component: File #E179259 UL Recognized Component (PAXT only): File #E156876 UL Listed Component: File #E137808 Type 4X Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Refer to EMC Installation Guidelines section of the bulletin for additional information. 17. CONNECTIONS: High compression cage-clamp terminal block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. 18. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use. IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and mounting clip included. 19. WEIGHT: 10.4 oz. (295 g) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |