| 数据搜索系统,热门电子元器件搜索 |
|
CBLUSB01 数据表(PDF) 6 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CBLUSB01 数据表(HTML) 6 Page - Red Lion Controls. Inc |
|
6 / 36 page ![]() 6 mOdel paXT - THermOCOUple and rTd inpUT THERMOCOUPLE AND RTD INPUTS CONFORMS TO ITS-90 STANDARDS CUSTOM SCALING FOR NON-STANDARD PROBES TIME-TEMPERATURE INTEGRATOR PAXT SPECIFICATIONS READOUT: Resolution: Variable: 0.1, 0.2, 0.5, or 1, 2, or 5 degrees Scale: F or C Offset Range: -19,999 to 99,999 display units THERMOCOUPLE INPUTS: Input Impedance: 20 MΩ Lead Resistance Effect: 0.03µV/ohm Max. Continuous Overvoltage: 30 V RTD INPUTS: Type: 3 or 4 wire, 2 wire can be compensated for lead wire resistance Excitation current: 100 ohm range: 165 µA 10 ohm range: 2.6 mA Lead resistance: 100 ohm range: 10 ohm/lead max. 10 ohm range: 3 ohms/lead max. Max. continuous overload: 30 V CUSTOM RANGE: Up to 16 data point pairs Input range: -10 to 65 mV 0 to 400 ohms, high range 0 to 25 ohms, low range Display range: -19999 to 99999 STANDARD *** ACCURACY* (0 to 50 °C) ACCURACY* (18 to 28 °C) RANGE no official standard 0.9°C 0.4°C -100 to 260°C 10 ohm Copper alpha = .00427 INPUT TYPE no official standard 0.5°C 0.2°C -80 to 260°C 120 ohm Nickel alpha = .00672 no official standard 1.6°C 0.4°C -200 to 850°C 100 ohm Pt alpha = .003919 IEC 751 1.6°C 0.4°C -200 to 850°C 100 ohm Pt alpha = .00385 0.20% of reading + 0.007 Ω 0.04% of reading + 0.005 Ω 0 to 25 Ω (1 MΩ res.) Custom 10 ohm range 0.12% of reading + 0.05 Ω 0.02% of reading + 0.04 Ω 0 to 400 Ω (10 MΩ res.) Custom 100 ohm range ACCURACY* (0 to 50 °C) 0.12% of reading + 5µV 0.02% of reading + 4µV -10 to 65mV (1 µV res.) Custom mV range ACCURACY* (18 to 28 °C) RANGE INPUT TYPE WIRE COLOR INPUT TYPE RANGE ACCURACY* (0 to 50 °C) STANDARD ANSI BS 1843 T -200 to 400°C -270 to -200°C 1.2°C ** 2.1°C ITS-90 (+) blue (-) red (+) white (-) blue E -200 to 871°C -270 to -200°C 1.0°C ** 2.4°C ITS-90 (+) purple (-) red (+) brown (-) blue J -200 to 760°C 1.1°C 2.3°C ITS-90 (+) white (-) red (+) yellow (-) blue K -200 to 1372°C -270 to -200°C 1.3°C ** 3.4°C ITS-90 (+) yellow (-) red (+) brown (-) blue R -50 to 1768°C 1.9°C 4.0°C ITS-90 no standard (+) white (-) blue S -50 to 1768°C 1.9°C 4.0°C ITS-90 no standard (+) white (-) blue B 100 to 300°C 300 to 1820°C 3.9°C 2.8°C 5.7°C 4.4°C ITS-90 no standard no standard N 1.3°C ** 3.1°C ITS-90 (+) orange (-) red (+) orange (-) blue C (W5/W26) 0 to 2315°C 1.9°C 6.1°C ASTM E988-90*** no standard no standard *After 20 min. warm-up. Accuracy is specified in two ways: Accuracy over an 18 to 28 °C and 15 to 75% RH environment; and Accuracy over a 0 to 50 °C and 0 to 85% RH (non condensing) environment. Accuracy specified over the 0 to 50 °C operating range includes meter tempco and ice point tracking effects. The specification includes the A/D conversion errors, linearization conformity, and thermocouple ice point compensation. Total system accuracy is the sum of meter and probe errors. Accuracy may be improved by field calibrating the meter readout at the temperature of interest. ** The accuracy over the interval -270 to -200 °C is a function of temperature, ranging from 1 °C at -200 °C and degrading to 7 °C at -270 °C. Accuracy may be improved by field calibrating the meter readout at the temperature of interest. *** These curves have been corrected to ITS-90. ACCURACY* (18 to 28 °C) -200 to 1300°C -270 to -200°C aCCessOries UNITS LABEL KIT (PAXLBK) - Not required for PAXT Each meter has a units indicator with backlighting that can be customized using the Units Label Kit. The backlight is controlled in the programming. Each PAXT meter is shipped with °F and °C overlay labels which can be installed into the meter’s bezel display assembly. EXTERNAL CURRENT SHUNTS (APSCM) To measure DC current signals greater than 2 ADC, a shunt must be used. The APSCM010 current shunt converts a maximum 10 ADC signal into 100.0 mV. The APSCM100 current shunt converts a maximum 100 ADC signal into 100.0 mV. The continuous current through the shunt is limited to 115% of the rating. PROGRAMMING SOFTWARE The Crimson software is a Windows based program that allows configuration of the PAX meter from a PC. Crimson offers standard drop-down menu commands, that make it easy to program the meter. The meter’s program can then be saved in a PC file for future use. A PAX serial option card or PAX USB programming card is required to program the meter using the software. Crimson can be downloaded at www.redlion.net. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |