| 数据搜索系统,热门电子元器件搜索 |
|
CBLUSB01 数据表(PDF) 21 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CBLUSB01 数据表(HTML) 21 Page - Red Lion Controls. Inc |
|
21 / 36 page ![]() 21 SETPOINT SELECTIONS - Select main or alternate setpoints - Reset Setpoint 1 (Alarm 1) - Reset Setpoint 2 (Alarm 2) - Reset Setpoint 3 (Alarm 3) - Reset Setpoint 4 (Alarm 4) - Reset Setpoint 3 & 4 (Alarm 3 & 4) - Reset Setpoint 2, 3 & 4 (Alarm 2, 3 & 4) - Reset Setpoint All (Alarm All) The following selections are accessible only with the Setpoint option card installed. Refer to Module 6 for an explanation of their operation. Setpoint Card Only PRINT REQUEST The meter issues a block print through the serial port when activated. The data transmitted during a print request is programmed in Module 7. If the user input is still active after the transmission is complete (about 100 msec), an additional transmission occurs. As long as the user input is held active, continuous transmissions occur. PROGRAM MODE SECURITY CODE* By entering any non-zero value, the prompt will appear when trying to access the Program Mode. Access will only be allowed after entering a matching security code or universal code of . With this lock-out, a user input would not have to be configured for Program Lock-out. However, this lock-out is overridden by an inactive user input configured for Program Lock-out. SP-1 SP-2 SP-3 SP-4 SETPOINT ACCESS* The setpoint displays can be programmed for , or (See the following table). Accessible only with the Setpoint option card installed. MAXIMUM DISPLAY LOCK-OUT* MINIMUM DISPLAY LOCK-OUT* TOTALIZER DISPLAY LOCK-OUT* These displays can be programmed for or . When programmed for , the display will not be shown when the DSP key is pressed regardless of Program Lock-out status. It is suggested to lock-out the display if it is not needed. The associated function will continue to operate even if its display is locked-out. 3-LOC LO HI tOt SP-1 SP-2 CodE PAR Pro Min Display Lock-out Max Display Lock-out Total Display Lock-out Setpoint 1 Access Security Code Setpoint 2 Access SP-3 Setpoint 3 Access SP-4 Setpoint 4 Access 6.3 mOdUle 3 - display and prOgram lOCK-OUT parameTers () PARAMETER MENU * Factory Setting can be used without affecting basic start-up. to Module 3 is the programming for Display lock-out and “Full” and “Quick” Program lock-out. When in the Display Mode, the available displays can be read consecutively by repeatedly pressing the DSP key. An annunciator indicates the display being shown. These displays can be locked from being visible. It is recommended that the display be set to when the corresponding function is not used. “Full” Programming Mode permits all parameters to be viewed and modified. This Programming Mode can be locked with a security code and/or user input. When locked and the PAR key is pressed, the meter enters a Quick Programming Mode. In this mode, the setpoint values can still be read and/or changed per the selections below. The Display Intensity Level () parameter also appears whenever Quick Programming Mode is enabled and the security code is greater than zero. SELECTION DESCRIPTION Visible but not changeable in Quick Programming Mode Visible and changeable in Quick Programming Mode Not visible in Quick Programming Mode Immediate access. “Full” Programming Not Active 0 No access Quick Programming Active 0 Immediate access. “Full” Programming Not Active >0 After Quick Programming with correct code # at prompt. Quick Programming w/Display Intensity Active >0 After Quick Programming with correct code # at prompt. Quick Programming w/Display Intensity ———— not >0 Immediate access. “Full” Programming ———— not 0 “FULL” PROGRAMMING MODE ACCESS WHEN PAR KEY IS PRESSED USER INPUT STATE USER INPUT CONFIGURED SECURITY CODE PROGRAMMING MODE ACCESS Throughout this document, Programming Mode (without Quick in front) always refers to “Full” Programming (all meter parameters are accessible). SELECTION DESCRIPTION Visible in Display Mode Not visible in Display Mode ì í î |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |