23 / 36 page ![]() 23 * Factory Setting can be used without affecting basic start-up. 5-tOt tbASE dECPt SCFAC Locut P-UP PAR Pro Totalizer Decimal Point Totalizer Time Base Totalizer Scale Factor Totalizer Low Cut Value Totalizer Power Up Reset 6.5 mOdUle 5 - TOTalizer (inTegraTOr) parameTers () PARAMETER MENU TOTALIZER DECIMAL POINT* For most applications, this matches the Input Display Decimal Point (). If a different location is desired, refer to Totalizer Scale Factor. TOTALIZER TIME BASE This is the time base used in Totalizer accumulations. If the Totalizer is being accumulated through a user input programmed for Batch, then this parameter does not apply. TOTALIZER SCALE FACTOR* For most applications, the Totalizer reflects the same decimal point location and engineering units as the Input Display. In these cases, the Totalizer Scale Factor is 1.000. The Totalizer Scale Factor can be used to scale the Totalizer to a different value than the Input Display. Common possibilities are: 1. Changing decimal point location (example tenths to whole) 2. Average over a controlled time frame. Details on calculating the scale factor are shown later. If the Totalizer is being accumulated through a user input programmed for Batch, then this parameter does not apply. TOTALIZER LOW CUT VALUE* to to A low cut value disables Totalizer when the Input Display value falls below the value programmed. The resolution of this parameter will be affected by the input rounding factor (1-INP, round). TOTALIZER POWER UP RESET* Reset buffer Do not reset buffer The Totalizer can be reset to zero on each meter power-up by setting this parameter to reset. - seconds (÷ 1) TOTALIZER HIGH ORDER DISPLAY When the total exceeds 5 digits, the front panel annunciator TOT flashes. In this case, the meter continues to totalize up to a 9 digit value. The high order 4 digits and the low order 5 digits of the total are displayed alternately. The letter “” denotes the high order display. When the total exceeds a 9 digit value, the Totalizer will show “E . . .” and will stop. TOTALIZER BATCHING The Totalizer Time Base and scale factor are overridden when a user input or function key is programmed for store batch (). In this mode, when the user input or function key is activated, the Input Display reading is one time added to the Totalizer (batch). The Totalizer retains a running sum of each batch operation until the Totalizer is reset. This is useful in weighing operations, when the value to be added is not based on time but after a filling event. TOTALIZER USING TIME BASE Totalizer accumulates as defined by: Input Display x Totalizer Scale Factor Totalizer Time Base Where: Input Display - the present input reading Totalizer Scale Factor - 0.001 to 65.000 Totalizer Time Base - (the division factor of ) Example: The input reading is at a constant rate of 10.0 gallons per minute. The Totalizer is used to determine how many gallons in tenths has flowed. Because the Input Display and Totalizer are both in tenths of gallons, the Totalizer Scale Factor is 1. With gallons per minute, the Totalizer Time Base is minutes (60). By placing these values in the equation, the Totalizer will accumulate every second as follows: 10.0 x 1.000 = 0.1667 gallon accumulates each second 60 This results in: 10.0 gallons accumulates each minute 600.0 gallons accumulates each hour TOTALIZER SCALE FACTOR CALCULATION EXAMPLES 1. When changing the Totalizer Decimal Point () location from the Input Display Decimal Point (), the required Totalizer Scale Factor is multiplied by a power of ten. Example: Input () = 0 Input () = 0.0 Input () = 0.00 (x = Totalizer display is round by tens or hundreds) 2. To obtain an average reading within a controlled time frame, the selected Totalizer Time Base is divided by the given time period expressed in the same timing units. Example: Average temperature per hour in a 4 hour period, the scale factor would be 0.250. To achieve a controlled time frame, connect an external timer to a user input programmed for . The timer will control the start (reset) and the stopping (hold) of the totalizer. - days (÷ 86400) - minutes (÷ 60) - hours (÷ 3600) The totalizer accumulates (integrates) the Input Display value using one of two modes. The first is using a time base. This can be used to compute a time- temperature product. The second is through a user input or function key programmed for Batch (one time add on demand). This can be used to provide a readout of temperature integration, useful in curing and sterilization applications. If the Totalizer is not needed, its display can be locked-out and this module can be skipped during programming. 0.001 x10 0.01 0 0.1 0.0 1 0.00 10 0.000 Scale Factor Totalizer Totalizer Scale Factor 0.0 10 0 1 x10 0.1 x100 0.01 x1000 0.001 Scale Factor 0.00 10 0.0 1 0 0.1 x10 0.01 x100 0.001 Totalizer |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |