24 / 37 page ![]() 10.2.1.3 Application Curves Performing a two-point calibration at 25°C removes the errors associated with offset voltage, gain error, and so forth. Figure 10-6 to Figure 10-8 show the measured error at different conditions. For a more detailed description on measurement procedure, calibration, and calculations, please refer to TIDU357. 0 0.5 1 1.5 2 2.5 3 -3 -2 -1 0 1 2 3 Load current (mA) C00 Figure 10-6. Measured Transfer Function ±800 ±600 ±400 ±200 0 200 400 600 800 ±3 ±2 ±1 0 1 2 3 Load current (mA) C00 -40°C 0°C 25°C 85°C 125°C Figure 10-7. Uncalibrated Error vs Load Current ±800 ±600 ±400 ±200 0 200 400 600 800 ±3 ±2 ±1 0 1 2 3 Load current (mA) C00 -40°C 0°C 25°C 85°C 125°C Figure 10-8. Calibrated Error vs Load Current REF2025, REF2030, REF2033, REF2041 SBOS600E – JULY 2018 – REVISED FEBRUARY 2022 www.ti.com 24 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated Product Folder Links: REF2025 REF2030 REF2033 REF2041 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|