11 / 19 page ![]() Using 75mA chopping immediatelly after stand by: The high resistive motor can be forced to chopping operation in the low current range. This leads to the samebehaviour as using a low resistive motor. Short to VS detection using high resistive motors: The short to VS flag is overwritten each time the chopper comparator responds. Having detected a short this flagonly can be reset by reaching chopping operation or resetting the circuit (ENN=1). For a high re- sistive motor thisleads to the following consequence: Once a short to VS is detected the error flag will persist even if the short is removed again until either a reset (ENN=1) or chopping (for example in 75mA mode) has taken place. We suggest to return to operation once a short to VS was detected by using the low current mode to reset the flag. Limitation of the Diagnosis The diagnosis depends on either detecting an overcurrent of more than typically 1.8A through the source transistor or on not detecting a flyback pulse, or on detecting severe overcurrents of the sink transistor immediately after turn on. Small currents bypassing the load will not be detected. In the low current range (hold current) the flyback pulse (especially commutating against the supply voltage after changing phase) may (depending on the inductivity of the stepper motor windings) be too short to be detected correctly. For this reason diagnosis using the flyback pulse is blanked at phase reversal at hold current. In the low current range (hold current) the current capability of the bridge is reduced on purpose. Short to VS may not be detected. In stead the bridge may just chop like normal operation. Flyback pulse detection is not blanked during PWM regulation at hold current (here commutation voltage is less than 1V thus providing a longer pulse duration.) This however should be taken in ac- count using stepper motors with low inductivity (less than 0.5mH). Using motors with such a low in- ductivity the flyback voltage in hold mode may decay too fast. Motors with extremely low ohmic resistance tend to pump up the current because current decay dur- ing flyback approaches zero while at bridge turn on the current will increase. This may lead to over- current detection. We suggest to use stepper motors with an ohmic resistance of approximately 3 Ω or more. Partial shorts of windings or shorts of stepper motors with coils in series may still yield a flyback pulses that are accepted by the diagnosis as a proper signal. Table 2. Error table. Error 1 bit7 Error 2 bit6 Description H H Normal operation L H Short to VS (sink overload immediately after turn on) shorted load (no flyback) open load (no flyback) H L short to gnd (source overload, missing flyback is masked) L L overtemperature prealarm At stepping rates faster than 1ms/data transfer error flags indicating a short should be used to initiate a pause of at least 1ms to allow the power bridges to cool down again. L9935 11/19 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |