| 数据搜索系统,热门电子元器件搜索 |
|
M41T94 数据表(PDF) 23 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M41T94 数据表(HTML) 23 Page - STMicroelectronics |
|
23 / 31 page ![]() 23/31 M41T94 Battery Low Warning The M41T94 automatically performs battery volt- age monitoring upon power-up and at factory-pro- grammed time intervals of approximately 24 hours. The Battery Low (BL) Bit, Bit D4 of Flags Register 0Fh, will be asserted if the battery voltage is found to be less than approximately 2.5V. The BL Bit will remain asserted until completion of bat- tery replacement and subsequent battery low monitoring tests, either during the next power-up sequence or the next scheduled 24-hour interval. If a battery low is generated during a power-up se- quence, this indicates that the battery is below ap- proximately 2.5 volts and may not be able to maintain data integrity in the SRAM. Data should be considered suspect and verified as correct. A fresh battery should be installed. If a battery low indication is generated during the 24-hour interval check, this indicates that the bat- tery is near end of life. However, data is not com- promised due to the fact that a nominal VCC is supplied. In order to insure data integrity during subsequent periods of battery back-up mode, the battery should be replaced. The SNAPHAT top may be replaced while VCC is applied to the de- vice. Note: This will cause the clock to lose time during the interval the SNAPHAT battery/crystal top is disconnected. The M41T94 only monitors the battery when a nominal VCC is applied to the device. Thus appli- cations which require extensive durations in the battery back-up mode should be powered-up peri- odically (at least once every few months) in order for this technique to be beneficial. Additionally, if a battery low is indicated, data integrity should be verified upon power-up via a checksum or other technique. tREC Bit Bit D7 of Clock Register 04h contains the tREC Bit (TR). tREC refers to the automatic continuation of the deselect time after VCC reaches VPFD. This al- lows for a voltage setting time before WRITEs may again be performed to the device after a power- down condition. The tREC Bit will allow the user to set the length of this deselect time as defined by Table 14. Initial Power-on Defaults Upon initial application of power to the device, the following register bits are set to a '0' state: Watch- dog Register, TR, FT, AFE, ABE, and SQWE. The following bits are set to a '1' state: ST, OUT, and HT (see Table 15). Table 14. tREC Definitions Note: 1. Default Setting Table 15. Default Values Note: 1. BMB0-BMB4, RB0, RB1. 2. State of other control bits undefined. 3. UC = Unchanged tREC Bit (TR) STOP Bit (ST) tREC Time Units Min Max 0 0 96 98 ms 01 40 200(1) ms 1 X 50 2000 µs Condition TR ST HT Out FT AFE ABE SQWE WATCHDOG Register(1) Initial Power-up (Battery Attach for SNAPHAT)(2) 01 110 00 0 0 Subsequent Power-up (with battery back-up)(3) UC UC 1 UC 0 0 0 0 0 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |