12 / 16 page ![]() ADIS16220 Preliminary Technical Data Rev. PrE | Page 12 of 16 Manual Capture Mode This is the factory-default mode, where the sensor waits for a user-driven trigger to execute a data capture. Set GLOB_CMD[11] = 1 (DIN = 0xBF08) to execute a data capture in this mode. Set CAPT_CTRL[7:0] = 0x02 to place the device in manual mode and enable the control bit that shuts the device down while it waits for the data capture command. Automatic Capture Mode In automatic mode, the device executes data captures without user input, on a periodic basis. Configuring the device for this mode requires three steps: program the capture period using CAPT_PRD, set the device in automatic mode using CAPT_CTRL[3:2], and start the capture process/clock using CLOB_CMD[11]. See Table 15 for an example of setting up automatic mode. Table 14. CAPT_PRD Register Bit Descriptions Bit Description (Default = 0x0000) [15:10] Not used [9:8] Scale 00 = 1 second/LSB 01 = 1 minute/LSB 10 = 1 hour/LSB [7:0] Data bits, binary format Table 15. Example Event Mode Configuration Sequence DIN Description 0x9F02, 0x9E18 Set time scale to hours Set the time between captures to 24 hours 0x9C06 Set the device for trigger mode and enable shutdown 0xBF08 Start: device executes a capture and shuts down Event Capture Mode The event capture mode triggers a data capture when the data meets the preset conditions in the alarm registers (ALM_xxxx). The ALM_CTRL register provides trigger source selection and configuration controls, while the ALM_MAGx registers provide threshold level controls. Table 16. ALM_CTRL Bit Descriptions Bit Description (Default = 0x0000) [15:6] Not used [5] System alarm comparison polarity 1 = trigger when less than ALM_MAGS[11:0] 0 = trigger when greater than ALM_MAGS[11:0] [4] System alarm trigger source 1 = temperature, 0 = power supply [3] System alarm enable (ALM_MAGS) 1 = enabled, 0 = disabled [2] AIN2 alarm enable (ALM_MAG2) 1 = enabled, 0 = disabled [1] AIN1 alarm enable (ALM_MAG1) 1 = enabled, 0 = disabled [0] Acceleration alarm enable (ALM_MAGA) 1 = enabled, 0 = disabled Table 17. ALM_MAGA Bit Descriptions Bit Description (Default = 0x0000) [15:0] Data bits for acceleration threshold setting; twos complement, 19.073 mg/LSB. Range = +8191/−8192 LSBs Table 18. ALM_MAG1 and ALM_MAG2 Bit Descriptions Bit Description (Default = 0x0000) [15:0] Data bits for AIN1, AIN2 signal threshold setting; twos complement, 305.18 μV/LSB. Range = +8191/−8192 LSBs Table 19. ALM_MAGS Bit Descriptions Bit Description (Default = 0x0000) [15:12] Not used. [11:0] Data bits for temperature or supply threshold setting. Binary format matches CAPT_TEMP or CAPT_SUPPLY format, depending on the ALM_CTRL[4] setting. Configuring the device in the event capture mode requires four steps: select which data channels to enable (ALM_CTRL), set each threshold (ALM_MAGx), select event capture mode (CAPT_CTRL) and start the capture mode operation (set GLOB_CMD[11]). Each ALM_MAGx register has a corresponding error flag in the DIAG_STAT register for software monitoring of alarm conditions. Note that the system alarm has an error flag in DIAG_STAT[11] but cannot trigger a data capture. Table 20. Example Event Mode Configuration Sequence DIN Description 0xA00C, 0xA102 Set acceleration trigger point at >+10 g and <−10 g by setting ALM_MAGA = 0x020C. 0xA634, 0xA700 Set temperature error flag level at +60°C by setting ALM_MAGS = 0x00C4. 0xA839 Set the system alarm as a greater-than-temperature configuration and enable both acceleration and system alarms by setting ALM_CTRL[7:0] = 0x39. 0xB61F Keep DIO1 as a busy indicator and set DIO2 as a positive alarm indicator by setting DIO_CTRL[7:0] = 0x1F. 0x9C5A Set capture into event mode, enable automatic capture store to flash, enable power-down between captures, and set pre-event capture length to 128 samples by setting CAPT_CTRL[7:0] = 0x5A. 0xBF08 Start the event capture mode by setting GLOB_CMD[11] = 1 GLOBAL COMMANDS The GLOB_CMD register provides an array of single-write commands for convenience. Setting the assigned bit in Table 21 to 1 activates each function. When the function completes, the bit restores itself to 0. For example, clear the capture buffers using a single DIN write sequence, DIN = 0xBF01. All of the commands in the GLOB_CMD register require the power supply to be within normal limits for the execution times listed in Table 21. The execution times reflect the factory default configuration where applicable and describe the time required to return to normal operation. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |