22 / 28 page ![]() WM9708 Advanced Information WOLFSON MICROELECTRONICS LTD AI Rev 2.0 April 2001 22 POWERDOWN CONTROL/STATUS REGISTER (INDEX 26h) This read/write register is used to program Powerdown states and monitor subsystem readiness. The lower half of this register is read only status, a 1 indicating that the subsection is ready. Ready is defined as the subsection able to perform in its nominal state. When this register is written the bit values that come in on AC-link will have no effect on read only bits 0 to 7. When the AC-link Codec Ready indicator bit (SDATAIN slot 0, bit 15) is a 1 it indicates that the AC- link and the WM9708 control and status registers are in a fully operational state. The AC’97 controller must further probe this Powerdown Control/Status Register to determine exactly which subsections, if any, are ready. READ BIT FUNCTION REF VREFs up to nominal level ANL Analogue mixers, etc ready DAC DAC section ready to accept data ADC ADC section ready to transmit data Table 10 Powerdown Status Register Function The powerdown modes are as follows. The first three bits are to be used individually rather than in combination with each other. The last bit PR3 can be used in combination with PR2 or by itself. PR0 and PR1 control the PCM ADCs and DACs only. PR6 is not supported by the WM9708. WRITE BIT FUNCTION PR0 PCM in ADCs and input Mux Powerdown PR1 PCM out DACs Powerdown PR2 Analogue mixer Powerdown (VREF still on) PR3 Analogue mixer Powerdown (VREF off) PR4 Digital interface (AC-link) Powerdown (external clock off) PR5 Internal clock disable PR6 HP amp Powerdown – not supported EAPD External amplifier Powerdown Table 11 Powerdown Control Register Function PR0 = 1 PR1 = 1 PR2 = 1 PR4 = 1 PR0 = 0 AND ADC = 1 DEFAULT READY = 1 COLD RESET WARM RESET PR2 = 0 AND ANL = 1 PR1 = 0 AND DAC = 1 ADCs OFF PR0 DACs OFF PR1 ANALOGUE OFF PR2 OR PR3 DIGITAL I/F OFF PR4 SHUT OFF CODA LINK NORMAL Figure 13 An Example of the WM9708 Powerdown/Powerup Flow Figure 13 illustrates one example procedure to do a complete Powerdown of the WM9708. From normal operation sequential writes to the Powerdown Register are performed to Powerdown the WM9708 a piece at a time. After everything has been shut off (PR0 to PR3 set), a final write (of PR4) can be executed to shut down the WM9708’s digital interface (AC-link). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |