7 / 20 page ![]() Data Sheet TLE 6232 GP V2.3 Page 2009-11-18 7 Description of the Power Stages 4 low side power switches for nominal currents up to 3A (power stages OUT1 to OUT4). Con- trol is possible by input pins or via SPI. For TJ = 150°C the on-resistance of the power switches is below 500m Ω. 2 low side power switches for nominal currents up to 1.5A (power stages OUT5 and OUT6). Control is possible by input pins or via SPI. For TJ = 150°C the on-resistance of the power switches is below 1 Ω. In order to increase the switching current or to reduce the power dissipation parallel connec- tion of power stages is possible. Each of the 6 output stages is equipped with its own zener clamp, which limits the output volt- age to a maximum of 60V. The outputs are provided with a current limitation set to a minimum of 1.5A resp. 3A. Each power stage is equipped with an own temperature sensor. Each output is protected by embedded protection functions 5). In case of overload or short- circuit to UBatt the current is internally limited and the corresponding bit combination is set (early warning). If this operation leads to an over-temperature condition, a second protection level (about 170°C) will change the output into a low duty cycle PWM (selective thermal shut- down with restart) to prevent critical chip temperatures. The following faults can be detected (individually for each output): - short to UBatt: (SCB/overload) can be detected when switches are On state - short to ground: (SCG) can be detected when switches are Off state - open load: (OL) can be detected when switches are Off state - over-temperature: (OT) will only be detected when switches are On state The fault conditions SCB, SCG and OL will not be stored until an integrated filtering time is expired (please note for PWM application). If, at one output, several errors occur in a se- quence, always the last detected error will be stored (with filtering time). All fault conditions are encoded in two bits per switch and are stored in the corresponding SPI registers. Additio- nally there are two central diagnostic bits: one especially for over-temperature (latched result of an OR-operation out of the 6 signals of the temperature sensor) and one for fault occur- rence at any output. A fault that has been detected and stored in the fault register must not be replaced by o.k.-state (11) unless it is read out by the RD_DIAG command sent by the micro- controller or an internal or external reset has been applied. I.e. the fault register will be cleared only by the RD_DIAG command. PRG - Program pin. PRG = High (VS): Parallel inputs Channel 1 to 6 are high active PRG = Low (GND): Parallel inputs Channel 1 to 6 are low active. If the parallel input pins are not connected (independent of high or low activity), channels 1 to 6 are switched OFF. PRG pin itself is internally pulled down when it is not connected. 5) The integrated protection functions prevent device destruction under fault conditions and may not be used in normal operation or permanently. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |