| 数据搜索系统,热门电子元器件搜索 |
|
80310 数据表(PDF) 26 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
80310 数据表(HTML) 26 Page - Freescale Semiconductor, Inc |
|
26 / 31 page ![]() Analog Integrated Circuit Device Data 26 Freescale Semiconductor 80310 FUNCTIONAL DEVICE OPERATION PROTECTION AND DIAGNOSIS FEATURES PROTECTION AND DIAGNOSIS FEATURES FAULT DETECTION General Notes All fault reporting passes through a 400 ms digital filter to avoid false indication problems, and transition from one fault type to another should be “clean”. MECHANICAL FAULT (F_MEC) The Phase is off (Low Phase RPM below stop_regulation threshold). Reported in Alternator A/B read data field (ID=11, 13), byte 1. ELECTRICAL FAULT (F_EL) If one of these faults appear: • The number of “1”s in all the OTP bits, NVM[80:1] is not ODD. The parity bit is included in the calculation • The Phase is on (Low Phase RPM above stop_regulation threshold) but High Phase 1 is not detected • B+A reaches 16.5 V with EXC at 100% DC • Short circuit excitation load • B+A stays at 75% of the target voltage when LRC is off Note: This 5th additional condition is enabled only when the NVM bit “Low Voltage Threshold” is enabled. Reported in Alternator A/B read data field (ID=11, 13), byte 1. ELECTRICAL FAULT (HP MASK) A fault detection when High phase signal is cut is reported on the electrical fault. Option (OTP) available to remove this fault detection. THERMAL FAULT (F_HT) A thermal fault is reported when the die temperature exceeds the programmed threshold. Reported in Alternator A/B read data field (ID=11, 13), byte 1. The programmed threshold in hexadecimal corresponds to the following temperature in degrees: • 6'b110010;//135degres • 6'b110100;//145degres • 6'b110110;//150degres • 6'b111001;//160degres ADDITIONAL ERRORS LIN Bus Timeout Check two timeouts: • Activity on RXD is below 3 or 8 seconds (depending on the OTP bit) • Time between two consecutive valid messages is below 3 or 8 seconds (depending on the OTP bit) This flag is reset once the microcontroller sends MID 11 for ALTA, or MID 13 for Alt B. Reported in Alternator A/B read data field (ID=11, 13), byte 2. Comm Error Checks the ID parity bits + Checksum byte + (TXD = RXD when responding) + LIN Physical layout not in over-current limitation. Reported in Alternator A/B read data field (ID=11, 13), byte 2. LIN protocol errors: • Sync Break Error: This flag is up when Synchro break Field duration is lower than 10Tbits. • Identifier parity Error: Comm error flag also reported in MID11 • Checksum Error: Comm error flag also reported in MID11 • Slave not responding Error: Tframe Max exceeded (LIN Specification revision 1.3). These flags are reset once the microcontroller sends MID 12 for ALTA, or MID 14 for Alt B. Reported in Alternator A/B read data field (ID=12, 14), byte 2. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |