| 数据搜索系统,热门电子元器件搜索 |
|
80310 数据表(PDF) 15 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
80310 数据表(HTML) 15 Page - Freescale Semiconductor, Inc |
|
15 / 31 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 15 80310 FUNCTIONAL DEVICE OPERATION STATE MACHINE LRC mode is active until the detection of phase stop regulating RPM (fSTOP). In this case, the device goes back to the pre-excitation mode. If the phase frequency reaches the LRC disable RPM default (fLRC), the device goes into regulation without LRC. REGULATION WITHOUT LRC: This mode is active when the phase frequency is above the LRC disable RPM default (fLRC), the first VREG was reached with LRC. The excitation is controlled only by the internal comparator of B+A and VREG. The DC can not be lower than DCMIN. If the phase frequency goes below the LRC disable RPM default (fLRC), then the 80310 comes back to the regulation with LRC mode. If the phase frequency goes below the phase stop regulating RPM, the device goes to pre-excitation mode. RE-REGULATION: The excitation is forced to 100%. This mode is active if there is no high phase on non active phase (PHx < VPH) in the previous cycle, until the high phase comes back. At the end of the 8th cycle, if there is still no high phase, the regulation mode is set off and the device goes back to the regulation mode with or without LRC. B+A is lower than VREG. In any case, DC cannot be lower than DCMIN. . Ph ase < LR C R EGUL ATION w LRC PR E-EXC No High Ph ase1 in th e pr ev io us cycle an d P hase Regu lation is ON Ph ase REG ULAT ION (High Phase1 appears) o r (1 00% DC du rin g 8 cycles = > Phase Regu lation set OF F) REG ULAT ION w/o LRC No Hig h Ph ase1 in th e pr eviou s cycle an d Ph ase Regu lation is ON P hase REGU LATION (High P hase1 ap pear s) or (10 0% DC d uring 8 cycles => Phase Regulation set OFF) P hase > Start Phase < Sto p Phase > LRC an d first Vreg reached with LR C Ph ase < Stop - POR - L IN Tim eo ut with no Ph ase - L IN M ID3 C if n vm _ lin _special Wake-u p on Pha se S tandby Ed ge on Phase . Restart tim er 10 0m s EX C 100% DC Ph ase > Star t_ aa . R estart timer 1 00 ms Hig h Ph ase1 ap pears Time out 100 m s Tim e ou t 100 m s LIN C om m and with V reg <> 1 0.6 V: - MID 29 if n vm _ALT1 - MID 2A if nv m _ALT 2 - MID 2B if nvm _lin_special Figure 10. Self-start State Machine This state machine runs only if self-start option has been programmed. STANDBY: The 80310 is in Standby mode if there is a LIN timeout, and in absence of alternator rotation (no phase), if power and reset (POR), or with a LIN MID3C command, if nvm_lin_special is set. • There is no excitation • The duty cycle (DC) is equal to zero The device needs a small amount of quiescent current to feed some functions such as oscillator. LIN timeout means: • No activity on the LIN bus during a specified time • or on a LIN watchdog timeout during a specified time WAKE-UP: This state is reached when an edge is detected on the phase (Phase voltage > Phase sensitivity) • The logic is out of reset |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |