| 数据搜索系统,热门电子元器件搜索 |
|
MAX1153 数据表(PDF) 17 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1153 数据表(HTML) 17 Page - Maxim Integrated Products |
|
17 / 30 page ![]() Stand-Alone, 10-Channel, 10-Bit System Monitors with Internal Temperature Sensor and VDD Monitor ______________________________________________________________________________________ 17 Read Global Configuration Register (Command Code 0101) The Read Global Configuration Register command, 0101, outputs the global configuration registers. The address bits following this command are ignored. When the MAX1153/MAX1154 receive a Read Global Configuration Register command, they output 5 bytes of data: 2 bytes from the channel enable register, 2 bytes from the input configuration register, and 1 byte from the setup register, all MSB first. See the Global Configuration Registers section for more details. RESET (Command Code 0111) The RESET command, 0111, resets the device. This command returns the MAX1153/MAX1154 to their power-on reset state, placing the device into shutdown mode. The address bits in the command are ignored. See the Power-Up/Reset Defaults Summary section for more details. Clear Channel Alarm for Selected Channel (Command Code 1000) The Clear Channel Alarm command, 1000, clears the alarm bits in the alarm register and resets the fault counter for the addressed channel. See the Alarm Register section for more details. See Table 3 for chan- nel addresses. Clear Alarm Register for All Channels (Command Code 1001) The Clear Alarm Register for All Channels command, 1001, clears the entire alarm register and resets the fault counters for the internal TEMP sensor, the VDD monitor, and the AIN0–AIN7 channels. The address bits in the command are ignored. See the Alarm Register section for more details. Write Current Data Register for Selected Channel (Command Code 1010) The Write Current Data Register for Selected Channel command, 1010, writes to the addressed channel’s cur- rent data register. This command sets an initial condi- tion when using the averaging filter option (see the Averaging section). This command can also be used for testing the thresholds, fault counters, and alarm functions (see Figure 8). See Table 3 for channel addresses. Write Current Data Register for All Channels (Command Code 1011) The Write Current Data Register for All Channels com- mand, 1011, writes to the current data registers of all channels sequentially, starting with the internal temper- ature sensor, then the VDD monitor, followed by chan- nels AIN0 to AIN7. The address bits are ignored. Use this command for testing and setting initial conditions when using the averaging filter option (see the Averaging section). C3 C2 C1 C0 A2 A1 A0 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 SCLK DIN DOUT A3 CS Figure 8. Serial Register Write Timing |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |