| 数据搜索系统,热门电子元器件搜索 |
|
MAX1153 数据表(PDF) 22 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1153 数据表(HTML) 22 Page - Maxim Integrated Products |
|
22 / 30 page ![]() Stand-Alone, 10-Channel, 10-Bit System Monitors with Internal Temperature Sensor and VDD Monitor 22 ______________________________________________________________________________________ Upper Threshold Register A conversion result greater than the value stored in the upper threshold register results in a fault, increasing the internal fault counter by one. When the fault count exceeds the value stored in fault bits B7–B4 of the chan- nel configuration register, the channel’s alarm bits in the alarm register are set, resulting in an interrupt on INT. The upper threshold register data format must be the same as the input channel. When the input channel is configured for single-ended or differential unipolar volt- age measurements, data stored in the upper threshold register is interpreted as straight binary. For input chan- nels configured for temperature measurements or as differential bipolar voltage inputs, the upper threshold register data is interpreted as two’s complement. Load the register with 3FF hex to disable upper threshold faults in unipolar mode, and 1FF hex in temperature or bipolar mode. The power-up/reset default is 3FF hex. See the Command Word section on how to read/write to the upper threshold registers. Lower Threshold Register Conversion results lower than the value stored in the lower threshold register increment the internal fault counter. Considerations about channel configuration register fault bits B7–B4, INT interrupts, and data for- mat are the same as for the upper threshold register. Set the register to 200 hex to disable lower threshold faults in unipolar mode, or to 200 hex in temperature or bipolar mode. The power-up/reset default is 000 hex. See the Command Word section on how to read/write to the lower threshold registers. Current Data Registers The current data register holds the last conversion result or the digitally averaged result, when enabled (see the Averaging section). The current data registers default to 800 hex at power-up/reset and can be read from and written to through the serial interface. See the Command Word section on how to read/write to the current data registers. INT Interrupt Output INT provides an indication that an alarm has occurred in the system. It can be programmed (see Table 9) to operate as a push-pull digital output or as an open- drain output (requiring either a pullup or a pulldown resistor) for wired-OR interrupt lines. Bits B3 and B4 in the setup register configure INT and determine its response to an alarm event. When an internal fault counter exceeds the threshold stored in the fault bits (B7–B4) of the corresponding chan- nel configuration register, the alarm bits for that particular channel are updated to indicate an alarm. When any bit in the alarm register is set, the INT output becomes active, and stays active until all alarm bits are cleared. See the Alarm Register section for more information. Servicing Interrupts at INT After detecting an interrupt on INT, the µC’s interrupt routine should first read the alarm register to find the source of the alarm and reset the alarm bits by using any of the methods described in the Alarm Register section. Then it can continue with any other action required by the application to react to the alarm. Note: Multiple alarm conditions can be present. The INT remains active until all alarm conditions have been cleared. Performing Conversions At power-up or after a RESET command, the MAX1153/MAX1154 default to shutdown mode with all channels enabled, set for single-ended voltage mea- surements, and with the scan mode set to manual. Start a conversion by issuing a manually triggered conver- sion command with the address bits of the channel selected (see the Manual Conversion section for more details) or by setting automatic scan mode. To place the MAX1153/MAX1154 in automatic scan mode, set the scan mode bit B2 in the setup register to logic 1. In automatic scan mode, the MAX1153/MAX1154 con- vert all enabled channels starting with the internal tem- perature sensor, followed by the VDD monitor, then by AIN0 to AIN7. As the scan sequence progresses, the analog inputs are converted and the resulting values are stored for each channel into its current data regis- ter. Once the scan cycle completes, the MAX1153/ MAX1154 wait a period determined by the sample wait bits (B7, B6, B5) in the setup register and then repeat the scan cycle. After configuring the MAX1153/MAX1154 with automat- ic scan mode enabled, the devices do not require any intervention from the system µC until an alarm is trig- gered. All conversion and monitoring functions can continue running indefinitely. Manual Conversion In manual mode (scan mode bit in the setup register set to zero, the default after power-up/reset), the MAX1153/MAX1154 convert individual channels with the Manually Triggered Conversion command. Assuming that, either by power-up/RESET defaults or by previous initialization, the channel to be addressed is both enabled and configured for the type of signal to be acquired (voltage/temperature, single ended/differen- tial, or unipolar/bipolar), carry out the following steps to |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |